Shop replacement repair parts for WeatherKing Air Conditioner model 10AJB030A01/Serial: 6933

Compressor

Dual Run Capacitor, 370 volt, 40+3 MFD.

Restore efficient cooling from your WeatherKing 10AJB030A01 central air conditioner with genuine OEM replacement parts from Repair Clinic. The 10AJB030A01 is a 2.5-ton R-22 single-stage cooling-only condensing unit in WeatherKing’s 10AJB series. WeatherKing is an ICP (International Comfort Products) brand; the 10AJB030A01 and its Heil, Tempstar, and Arcoaire equivalents at the same configuration share identical components and are interchangeable across all four brand designations. The serial prefix 6933 in the 10AJB030A01/Serial: 6933 designation identifies the production date range and does not affect parts compatibility for capacitors, contactors, fan motors, or fan blades. Parts most frequently replaced on the 10AJB030A01/Serial: 6933 Air Conditioner include the run capacitor, contactor, condenser fan motor, and control board. Use the 10AJB030A01/Serial: 6933 parts list to confirm your component, then browse the full ICP central air conditioner parts catalog.
The WeatherKing 10AJB030A01 is a 10-SEER R-22 refrigerant condensing unit, representing a prior-generation efficiency and refrigerant standard compared to current R-410A systems. R-22 is no longer manufactured for new equipment and is subject to supply restrictions; all refrigerant service on the 10AJB030A01 must be performed by an EPA Section 608 certified technician using reclaimed or recovered R-22. The mechanical components of the 10AJB030A01 including the capacitor, contactor, fan motor, and control board are not refrigerant-dependent and remain fully serviceable with OEM ICP parts. The serial prefix 6933 identifies the production week and year of manufacture; for most service components this serial date has no impact on parts selection. The related 10AJB18A01 and 10AJB24A01 are 1.5-ton and 2-ton configurations in the same ICP 10AJB series; components from these tonnage configurations are not interchangeable with the 10AJB030A01 fan motor or blade. The 10AJB030A01/Serial: 6933 manual documents the R-22 refrigerant charge specification, electrical data, and component locations. For diagnostic guidance, visit the ICP air conditioner troubleshooting section.
The 10AJB030A01/Serial: 6933 capacitor is a dual-run unit that has accumulated service hours through all the cooling seasons since the unit was manufactured. A capacitor in a long-service unit may be at or near end of life regardless of visual condition; physical swelling is a late-stage indicator of failure, not an early one. Annual testing with a microfarad meter at the start of each cooling season is the most reliable way to confirm whether the capacitor still meets specification. Replace the capacitor when either the compressor or fan motor section reads more than five percent below the rated value on the label, and consider proactive replacement without testing on any 10AJB030A01 with an original capacitor that has been in service for ten or more years. Browse ICP central air conditioner capacitor parts.
The contactor on the WeatherKing 10AJB030A01 has switched line voltage to the 2.5-ton compressor and condenser fan motor at every thermostat cooling cycle since the unit was placed in service. Arc erosion on the contact faces accumulates progressively; on a long-service unit the contact faces may have eroded well beyond the point of acceptable resistance even when the contactor still closes and the unit still starts. A 10AJB030A01 compressor that trips its internal thermal overload repeatedly under normal ambient temperatures, or one that has been running warmer than it should without a clear refrigerant or airflow cause, may have a contactor delivering reduced voltage due to face erosion. Proactive contactor replacement on any 10AJB030A01 that has been in service for seven or more years is a sound preventive measure. Find compatible options at the ICP air conditioner contactor page.
The condenser fan motor on the 10AJB030A01/Serial: 6933 Air Conditioner has operated through multiple cooling seasons of startup-and-shutdown cycling that stresses motor bearings independent of total running hours. A motor that starts noisily and quiets after warming up has bearings that are beginning to deteriorate under thermal cycling stress even if total operating hours remain relatively low. Listen for any bearing noise at the first startup of each cooling season; a motor showing early bearing noise at seasonal startup should be scheduled for replacement before the bearing fully seizes, which would leave the unit without cooling during peak-demand conditions. Browse ICP central air conditioner fan motor parts for compatible 2.5-ton replacements.
The control board on the WeatherKing 10AJB030A01 manages the unit’s operational sequence, safety monitoring, and thermostat communication. On long-service units, onboard electrolytic capacitors age and dry out, causing intermittent board behavior that is more difficult to diagnose than a clean failure; the unit may start and stop erratically rather than failing to start completely. Before ordering a control board replacement, verify 24-volt control circuit input voltage at the board terminals and confirm the thermostat is sending a valid cooling call; a failed 24-volt transformer or broken low-voltage wire produces identical symptoms at lower replacement cost. Browse ICP central air conditioner control board parts.
The WeatherKing 10AJB030A01 is a 10-SEER R-22 era unit manufactured before the industry transition to R-410A refrigerant. R-22 is no longer manufactured for new equipment and requires EPA Section 608 certification for handling. The mechanical service components including the 10AJB030A01/Serial: 6933 capacitor, contactor, fan motor, and control board are not refrigerant-dependent and remain fully serviceable with OEM ICP parts available through Repair Clinic.
Electrical components including the capacitor and contactor may be shared across some 10AJB series configurations, but the fan motor and fan blade are output-class specific. The 10AJB18A01 (1.5-ton), 10AJB24A01 (2-ton), and 10AJB030A01 (2.5-ton) motors and blades are sized for their respective condenser coils and are not interchangeable. Always confirm the 030 output class designation when ordering fan motor and blade components for the 10AJB030A01.
The 6933 serial prefix identifies the production week and year of manufacture for this specific unit. For the run capacitor, contactor, fan motor, and fan blade, this serial date has no impact on parts compatibility within the 10AJB030A01 model. For control boards and wiring harnesses, confirm the serial range is covered in the specific listing before ordering to ensure the correct production generation component.
A 10AJB030A01 that hums at startup and then shuts off with no cooling typically has a failed compressor section on the dual-run run capacitor. The compressor attempts to start, cannot develop adequate starting torque without full capacitor support, and trips its internal thermal overload protector within seconds. Test the capacitor microfarad values before any other diagnosis; this symptom resolves with 10AJB030A01/Serial: 6933 capacitor replacement in the majority of cases without requiring compressor or contactor service.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.