Rheem RGPH-10AMER/Serial: EM Furnace Parts

Shop replacement repair parts for Rheem Furnace model RGPH-10AMER/Serial: EM

icons/furnace
Brand:Rheem
Model:RGPH-10AMER/Serial: EM
Product:Furnace
41 results
Product is a manufacturer part
42-24194-82 Pressure Switch
$45.80

Pressure switch-This pressure switch kit replaces pressure switches: 42-101233-02, 42-23648-03, 42-24064-01, 42-24194-02, 42-24335-03 and 42-22682-03.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
46-101496-01 Transformer
$41.28

Transformer, 120 Volts Primary, 24 Volt Secondary, 40VA

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
70-24157-03 Draft Inducer Motor
$340.40

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
60-105055-01 Gas Valve Assembly
$242.40

24v 1/2" x 1/2" direct spark ignition standard open Natural Gas

Go

Rheem RGPH-10AMER/Serial: EM Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Rheem RGPH-10AMER/Serial: EM problems ― and their solutions. Do any of these look familiar?
Furnace not heating
22 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
11 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
13 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Flame Rollout Limit Switch
Door Switch
Pressure Switch

Keep your Rheem RGPH-10AMER/Serial: EM heating through every season with genuine OEM replacement parts from Repair Clinic. The 10 code places this RGPH furnace in the 100,000 BTU input class, the largest common size in the series, and the EM serial prefix identifies its production range. Rheem and Ruud share one manufacturing platform, so equivalent Ruud models use the same service components. Parts replaced most often include the RGPH-10AMER/Serial: EM draft inducer motor, the flame sensor, the ignition parts, and the control board. Check your build on the RGPH-10AMER/Serial: EM parts list, then browse the full Rheem furnace parts catalog.

RGPH-10AMER/Serial: EM Furnace Details

This RGPH-10AMER/Serial: EM furnace is a non-condensing gas unit with a multi-speed PSC blower, so there is no condensate trap to service. At 100,000 BTU it moves more heat than the 07 size, and burners, orifices, and the blower are matched to that input. Its parts list includes a NOx insert retainer, which means some builds carry low NOx inserts in the burner area; reinstall them in the same position after burner service. The list also shows gas valves for both direct spark and hot surface ignition, so confirm your ignition type on the RGPH-10AMER/Serial: EM diagram. The RGPH-10AMER/Serial: EM manual documents the sequence of operation and LED fault codes. For RGPH-10AMER/Serial: EM repair steps, open the model troubleshooting page.

Most Replaced RGPH-10AMER/Serial: EM Furnace Parts

Ignition Source and No-Fire Starts

Read the fault code first. If the inducer runs and the pressure switch closes but the burner never lights, inspect the ignition source your diagram shows: hot surface elements crack with age, while spark electrodes fail from worn gaps or damaged leads. Order the RGPH-10AMER/Serial: EM igniter that matches your build from the ignition parts filter.

Flame Sensor Carbon Fouling

The RGPH-10AMER/Serial: EM flame sensor proves combustion through flame rectification. Carbon film on the rod reduces the signal, so the burner lights and shuts down within seconds. Clean the rod yearly with fine steel wool, and replace the flame sensor when cleaning no longer restores operation.

Draft Inducer and Pressure Switch Sequence

The inducer must prove draft before ignition proceeds. A motor that runs but never closes the pressure switch points to a restricted flue, cracked tubing, or a weak motor. Check the vent first, then confirm motor speed before replacing the inducer motor or the pressure switch.

Control Board Fault Codes

Board failures are less common than the faults they report. Replace the control board only after the ignition parts, flame sensor, inducer, and pressure switch test good, and match it to the RGPH-10AMER/Serial: EM serial range.

Why Choose Repair Clinic for Rheem RGPH-10AMER/Serial: EM Parts

  • Rheem and Ruud OEM Parts: Genuine parts from the shared Rheem and Ruud platform. Browse all Rheem furnace parts.
  • 100,000 BTU Matching: Burner, orifice, and blower parts are sized for this input, and NOx insert hardware is listed where your build uses it.
  • Sequence-Based Diagnosis: Read the code and test ignition, flame sensing, and draft before replacing the board.
  • Shop RGPH-10AMER/Serial: EM Parts Online: In-stock RGPH-10AMER/Serial: EM replacement parts and RGPH-10AMER/Serial: EM parts ship the same day with a 365-day return policy.

Rheem RGPH-10AMER Furnace FAQ

Why does my furnace start and then shut off after a few seconds?

A fouled flame sensor is the most common cause. Carbon on the rod weakens the signal, so the board closes the gas valve. Clean the rod, and replace the sensor if the symptom continues.

Is this a packaged unit?

No. It is cataloged as a gas furnace with its own blower. Parts for the burner, inducer, ignition, and controls are listed on this page by position in the cabinet.

What are the NOx inserts in the burner area?

They are inserts some builds use to lower nitrogen oxide emissions. If your furnace has them, reinstall them in the same position after burner or heat exchanger service.

Does the RGPH-10AMER/Serial: EM heat exchanger need inspection?

Have it inspected if the rollout switch trips, you see scorching near the burners, or limit trips continue with a clean filter and good airflow.