Rheem RGTA-06EMAES/Serial: FY Furnace Parts

Shop replacement repair parts for Rheem Furnace model RGTA-06EMAES/Serial: FY

icons/furnace
Brand:Rheem
Model:RGTA-06EMAES/Serial: FY
Product:Furnace
90 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
93247 Silicone Sealant
$25.83

2.8 oz Tube of Red Devil High Temp RTV Silicone. Perfect for Gasket replacement. Not for Heat Exchangers.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
70-24033-01 Draft Inducer Motor
$368.64

Induced draft blower motor with gasket, 120 volts. Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
62-24140-04 Control Board
$188.68

Integrated furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
46-101496-01 Transformer
$41.28

Transformer, 120 Volts Primary, 24 Volt Secondary, 40VA

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
60-105055-01 Gas Valve Assembly
$242.40

24v 1/2" x 1/2" direct spark ignition standard open Natural Gas

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
FP-02 Conversion Kit
$63.00

Natural to Lp Conversion Kit. *Should be installed by a certified Rheem repairperson.

Go

Rheem RGTA-06EMAES/Serial: FY Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Rheem RGTA-06EMAES/Serial: FY problems ― and their solutions. Do any of these look familiar?
Furnace not heating
31 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
10 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
14 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Igniter
Silicone Sealant
Spark Electrode

Keep your Rheem RGRA-06EMAES furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The 06EMAES/Serial: FY is a 60,000 BTU upflow condensing gas furnace from Rheem’s Achiever 90 Plus series, achieving over 90% AFUE through a secondary heat exchanger that produces acidic condensate during normal heating operation. It is the smallest output configuration in the RGRA condensing line, designed for well-insulated smaller homes or supplemental heating applications where 90,000 or 100,000 BTU would exceed the heating load. Repair Clinic stocks genuine Rheem OEM parts for the RGRA-06EMAES including the Rheem igniter parts, Rheem flame sensor parts, Rheem draft inducer motor parts, Rheem pressure switch parts, and Rheem control board parts. Browse the Rheem furnace parts catalog filtered by 06EMAES/Serial: FY for the complete parts inventory.

RGRA-06EMAES: Achiever 90 Plus 60,000 BTU Condensing Platform and Its 90,000 and 100,000 BTU Siblings

The Rheem RGRA-06EMAES at 60,000 BTU, the RGTA-09EZAJS at 90,000 BTU, and the RGRA-10EZAJS at 100,000 BTU all share the same Achiever 90 Plus condensing platform but use inducer motors sized for their respective output classes. The condensing-rated inducer on the 06EMAES/Serial: FY must tolerate moisture from condensate-laden flue gases and must never be substituted with a standard 80% AFUE inducer. A blocked condensate drain is the most common cause of pressure switch faults on the RGRA-06EMAES. The Rheem furnace troubleshooting guide covers Achiever 90 Plus fault code interpretation.

Most Replaced Parts on the Rheem RGRA-06EMAES

Condensate Trap for the RGRA-06EMAES

Annual flushing of the condensate trap at the beginning of the heating season is the single most cost-effective preventive maintenance step for the RGRA-06EMAES. Algae growth in the trap during the warm-weather idle period causes most pressure switch fault calls at early heating season startup on the Achiever 90 Plus platform.

Rheem RGRA-06EMAES Draft Inducer Motor

The condensing-rated inducer on the 06EMAES/Serial: FY is sized for 60,000 BTU combustion gas throughput. It must tolerate moisture from condensate-laden flue gases that would quickly corrode a standard 80% AFUE inducer. A standard 80% inducer must never be substituted. Bearing failure presents as grinding at startup during the pre-purge phase.

Pressure Switch Assembly for the RGRA-06EMAES

Inspect and flush the condensate drain trap before replacing the pressure switch on any condensing furnace. The vast majority of 06EMAES/Serial: FY pressure switch fault calls trace to a blocked condensate drain rather than a failed switch diaphragm.

Hot Surface Igniter for the RGRA-06EMAES

The igniter on the RGRA-06EMAES functions identically to igniters in any Rheem gas furnace regardless of the condensing platform. Testing resistance at room temperature with power off confirms or rules out igniter failure in under two minutes.

RGRA-06EMAES Control Board

The control board manages condensate monitoring and ignition sequencing specific to the Achiever 90 Plus condensing platform. It is not interchangeable with boards from the non-condensing Rheem RGPH Classic series. Document the LED fault code before ordering any replacement component.

Why Choose Repair Clinic for Rheem 06EMAES/Serial: FY Parts

  • Genuine Rheem Achiever 90 Plus OEM Components: 60,000 BTU condensing-rated inducers, pressure switch assemblies, and control boards confirmed for the RGRA-06EMAES Rheem furnace parts.
  • Ruud UGRA Cross-Reference: Parts for the Ruud-branded equivalent of the Achiever 90 Plus platform are cross-catalogued where interchangeable with the Rheem 06EMAES/Serial: FY.
  • Condensate System Priority: Annual drain trap flushing guides prevent the most common RGRA-06EMAES pressure switch fault from recurring at every heating season startup.
  • 365-Day Returns: Return any uninstalled Rheem part within a full year of purchase with no restocking fees.

Rheem RGRA-06EMAES Furnace Parts FAQ

Is the Rheem RGRA-06EMAES related to the Ruud UGRA series?

Yes. The Rheem RGRA and Ruud UGRA are the same condensing furnace platform sold under different brand names. The RGRA-06EMAES and its Ruud equivalent share all service components, and parts are fully interchangeable between both brand designations.

Why does my RGRA-06EMAES produce a pressure switch fault at the start of the heating season?

Early-season pressure switch faults on the RGRA-06EMAES are almost always caused by algae growth in the condensate trap during the warm months when the furnace was idle. Flushing the condensate trap with clean water before the first heating call each season prevents this recurring fault.

What type of venting does the Rheem RGRA-06EMAES require?

The RGRA-06EMAES is a condensing furnace requiring Schedule 40 PVC venting for both exhaust and combustion air intake. Metal B-vent is not appropriate for this model because it cannot tolerate the acidic condensate that forms in the flue gases of a condensing furnace.