Shop replacement repair parts for Rheem Furnace model RGTA-10EZAJS/Serial: FY

icons/furnace
Brand:Rheem
Model:RGTA-10EZAJS/Serial: FY
Product:Furnace
91 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
93247 Silicone Sealant
$25.83

2.8 oz Tube of Red Devil High Temp RTV Silicone. Perfect for Gasket replacement. Not for Heat Exchangers.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
70-24033-01 Draft Inducer Motor
$368.64

Induced draft blower motor with gasket, 120 volts. Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
62-24140-04 Control Board
$188.68

Integrated furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
46-101496-01 Transformer
$41.28

Transformer, 120 Volts Primary, 24 Volt Secondary, 40VA

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
60-105055-01 Gas Valve Assembly
$242.40

24v 1/2" x 1/2" direct spark ignition standard open Natural Gas

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
FP-02 Conversion Kit
$63.00

Natural to Lp Conversion Kit. *Should be installed by a certified Rheem repairperson.

Go

Rheem RGTA-10EZAJS/Serial: FY Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Rheem RGTA-10EZAJS/Serial: FY problems ― and their solutions. Do any of these look familiar?
Furnace not heating
31 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
11 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
14 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Igniter
Silicone Sealant
Spark Electrode

Keep your Rheem RGTA-10EZAJS/Serial: FY furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The RGTA-10EZAJS/Serial: FY is a 100,000 BTU upflow condensing gas furnace from Rheem’s Achiever 90 Plus series, achieving over 90% AFUE through a secondary heat exchanger that extracts latent heat from flue gases and produces acidic condensate. The Ruud UGRA-10EMAES is the brand-equivalent of the same platform. Repair Clinic stocks genuine Rheem OEM parts for the RGTA-10EZAJS/Serial: FY including the Rheem draft inducer motor parts, pressure switch assembly, Rheem furnace control board parts, condensate trap, and Rheem igniter parts. Browse the Rheem furnace parts catalog filtered by RGTA-10EZAJS/Serial: FY for the complete parts inventory.

RGTA-10EZAJS/Serial: FY: Achiever 90 Plus Condensing Platform Service Requirements

The Rheem RGTA-10EZAJS/Serial: FY operates differently from the non-condensing RGPH Classic series and requires condensing-specific service knowledge. A blocked condensate drain is the most common cause of pressure switch faults on the RGTA-10EZAJS/Serial: FY. The condensing-rated inducer on the RGTA-10EZAJS/Serial: FY tolerates moisture from condensate-laden flue gases and must not be substituted with a standard 80% inducer. The Ruud UGRA-10EMAES shares the same platform and service parts.

Most Replaced Parts on the Rheem RGTA-10EZAJS/Serial: FY

Condensate Trap for the RGTA-10EZAJS/Serial: FY

Annual flushing of the condensate trap at the beginning of the heating season is the single most cost-effective preventive maintenance step for the RGTA-10EZAJS/Serial: FY. Algae growth and debris accumulation block drainage and cause pressure switch faults.

Rheem RGTA-10EZAJS/Serial: FY Draft Inducer Motor

The condensing-rated inducer is designed to tolerate moisture from condensate-laden flue gases. A standard 80% inducer from the non-condensing RGPH platform must not be substituted, it will fail prematurely. Bearing failure presents as grinding at startup during the pre-purge phase.

Pressure Switch Assembly for the RGTA-10EZAJS/Serial: FY

Before replacing the switch, inspect the pressure hose for cracks and verify the condensate drain is clear. A blocked drain is responsible for the majority of pressure switch fault calls on this platform.

Control Board for the Rheem RGTA-10EZAJS/Serial: FY

The RGTA-10EZAJS/Serial: FY control board manages condensate pump monitoring, inducer operation, and ignition sequencing specific to the Achiever 90 Plus condensing platform. It is not interchangeable with boards from the non-condensing RGPH Classic series.

Hot Surface Igniter for the RGTA-10EZAJS/Serial: FY

The igniter on the RGTA-10EZAJS/Serial: FY functions identically to igniters in any Rheem gas furnace. Annual inspection for cracks during seasonal startup identifies worn igniters before they cause a lockout.

Why Choose Repair Clinic for Rheem RGTA-10EZAJS/Serial: FY Parts

  • Genuine Rheem Achiever 90 Plus OEM Components: Condensing-rated inducers, pressure switch assemblies, and control boards confirmed for the RGTA-10EZAJS/Serial: FY — Rheem furnace parts.
  • Ruud UGRA-10EMAES Cross-Reference: Parts for the Ruud-branded equivalent are cross-catalogued where interchangeable with the Rheem RGTA-10EZAJS/Serial: FY — Rheem furnace parts.
  • Condensate System Guidance: Annual drain trap flushing guides and PVC vent slope requirements prevent the repeat pressure switch faults most common on the Achiever 90 Plus platform.
  • 365-Day Returns: Return any uninstalled Rheem part within a full year of purchase with no restocking fees.

Rheem RGTA-10EZAJS Furnace Parts FAQ

What is the efficiency and BTU output of the Rheem RGTA-10EZAJS/Serial: FY?

The RGTA-10EZAJS/Serial: FY is a 100,000 BTU input condensing gas furnace from Rheem’s Achiever 90 Plus series, achieving over 90% AFUE. The Ruud UGRA-10EMAES is the brand-equivalent of the same condensing platform.

Is the Rheem RGTA-10EZAJS the same as the Ruud UGRA-10EMAES?

Yes. The Rheem RGRA and Ruud UGRA are the same condensing furnace platform sold under different brand names. Service parts are interchangeable between both designations.

What type of venting does the Rheem RGTA-10EZAJS/Serial: FY require?

The RGTA-10EZAJS/Serial: FY is a condensing furnace requiring Schedule 40 PVC plastic venting for both the exhaust and combustion air intake. Metal B-vent is not appropriate. Horizontal PVC sections must slope back toward the unit so condensate drains back rather than pooling.

My Rheem RGTA-10EZAJS/Serial: FY has a pressure switch fault. Where should I start?

Inspect the condensate drain first. A blocked condensate drain backs liquid into the secondary heat exchanger, preventing the inducer from establishing the correct draft the pressure switch must verify. Clearing the condensate drain resolves the majority of pressure switch fault calls on the Achiever 90 Plus platform.