Ruud Furnace UGRA-07EMAES/Serial: EH Parts

Shop replacement repair parts for Ruud Furnace model UGRA-07EMAES/Serial: EH

icons/furnace
Brand:Ruud
Model:UGRA-07EMAES/Serial: EH
Product:Furnace
74 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
93247 Silicone Sealant
$25.83

2.8 oz Tube of Red Devil High Temp RTV Silicone. Perfect for Gasket replacement. Not for Heat Exchangers.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
70-24033-01 Draft Inducer Motor
$368.64

Induced draft blower motor with gasket, 120 volts. Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
46-101496-01 Transformer
$41.28

Transformer, 120 Volts Primary, 24 Volt Secondary, 40VA

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
60-105055-01 Gas Valve Assembly
$242.40

24v 1/2" x 1/2" direct spark ignition standard open Natural Gas

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
FP-02 Conversion Kit
$63.00

Natural to Lp Conversion Kit. *Should be installed by a certified Rheem repairperson.

Go

Ruud UGRA-07EMAES/Serial: EH Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Ruud UGRA-07EMAES/Serial: EH problems ― and their solutions. Do any of these look familiar?
Furnace not heating
25 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
12 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Igniter
Silicone Sealant
Spark Electrode

Keep your Ruud UGRA-07EMAES furnace running dependably with genuine OEM replacement parts from Repair Clinic. The UGRA-07EMAES is a Ruud Achiever series residential gas furnace; Rheem and Ruud are sister brands under the same parent company sharing the same manufacturing platform, making all UGRA-07EMAES components interchangeable with the equivalent Rheem residential furnace designation at the same configuration. The Serial: EH prefix identifies the production period for this specific unit; for primary ignition components like the igniter and flame sensor, the serial prefix has limited impact on parts compatibility, but confirm against the specific listing for control board ordering. Parts most frequently replaced include the igniter, flame sensor, control board, blower motor, and draft inducer motor. Use the UGRA-07EMAES parts list and browse the full Ruud furnace parts catalog.

Ruud UGRA-07EMAES: Achiever Series Platform and Rheem Sister Brand Equivalence

The Ruud UGRA-07EMAES is part of the Ruud Achiever series of residential gas furnaces. Ruud and Rheem are sister brands under the same parent company; OEM parts for the UGRA-07EMAES are manufactured to the same factory standards as Rheem equivalents, making them fully interchangeable at the same model configuration. Confirming the correct part using your full model number including the Serial: EH production identifier is best practice before ordering, particularly for the control board where specifications can vary between production runs. For diagnostic guidance, visit the Ruud furnace troubleshooting section.

Essential UGRA-07EMAES Replacement Parts and Diagnostic Sequences

Ruud UGRA-07EMAES Furnace Igniter

The hot surface igniter on the UGRA-07EMAES initiates every heating cycle by heating to the temperature required to light the gas burner. A no-heat condition where the inducer runs normally and the pressure switch closes but no flame appears points directly to igniter failure as the first component to inspect. Replace a worn igniter with a genuine OEM part to restore reliable ignition and protect the burner system from repeated failed startup attempts. Browse Ruud furnace igniter parts.

Flame Sensor for Your UGRA-07EMAES Furnace

The flame sensor confirms combustion is occurring after the gas valve opens by detecting the small electrical current that passes through an ionized flame. As oxidation builds on the sensor rod, its conductivity degrades below the control board’s minimum confirmation threshold, causing the furnace to light briefly and shut down repeatedly before entering lockout. This is one of the most common service items on any gas furnace. Browse Ruud furnace flame sensor parts.

Ruud UGRA-07EMAES Control Board

The UGRA-07EMAES control board coordinates the inducer purge cycle, igniter activation, gas valve control, flame confirmation, and blower timing. Because the control board interacts with every other system in the furnace, testing the igniter, flame sensor, pressure switch, and limit switch individually before ordering a replacement board is the recommended diagnostic approach. A genuine OEM board ensures full compatibility with the UGRA-07EMAES wiring harness and Serial: EH production configuration. Browse Ruud furnace control board parts.

UGRA-07EMAES Draft Inducer Motor

The draft inducer motor draws combustion air into the burner chamber and exhausts flue gases before and during each heating cycle. It also creates the negative pressure the pressure switch monitors before allowing ignition to proceed. A slow-running inducer can produce pressure switch faults even when the switch itself tests functional. Browse Ruud furnace inducer motor parts.

UGRA-07EMAES Blower Motor

The blower motor drives the fan that circulates return air through the heat exchanger and delivers heated air through the supply ductwork. A motor that hums but does not spin typically has a failed run capacitor; test the capacitor before ordering a replacement motor. Browse Ruud furnace blower motor parts.

Ruud UGRA-07EMAES Parts at Repair Clinic

  • Genuine Ruud OEM Parts for the UGRA-07EMAES Achiever Series Platform: Every component meets manufacturer standards with Rheem platform cross-reference. Browse the full Ruud furnace parts catalog.
  • Ruud-Rheem Platform Equivalence: The UGRA-07EMAES and its Rheem equivalent share the same manufacturing platform; all service components are interchangeable between both brand designations.
  • Serial: EH Production Context: The EH serial prefix has limited impact on igniter and flame sensor compatibility but should be confirmed for control board ordering.
  • 365-Day Returns and Fast Shipping: All UGRA-07EMAES parts ship promptly. The Ruud furnace troubleshooting section provides step-by-step diagnostic guidance.

Ruud UGRA-07EMAES Furnace Parts FAQ

What are the most commonly replaced parts for the Ruud UGRA-07EMAES furnace?

The igniter, flame sensor, and control board are the most frequently replaced components on the UGRA-07EMAES. The draft inducer motor and blower motor are also common service items as the furnace accumulates operating hours. All of these components are directly involved in the heating cycle and experience the most thermal and mechanical stress over the furnace’s service life.

Why does my UGRA-07EMAES furnace start and then shut off shortly after?

Short cycling on the Ruud UGRA-07EMAES is most often caused by a dirty or degraded flame sensor that cannot electrically confirm the burner flame, triggering a safety shutdown. A tripping high-limit switch from restricted airflow and a faulty pressure switch from cracked pressure tubing can produce the same behavior. Cleaning or replacing the flame sensor is the most practical first step when the furnace lights and shuts off repeatedly before lockout.

Where can I find the UGRA-07EMAES parts diagram?

The Ruud UGRA-07EMAES parts diagram is available on the Repair Clinic product page under the Diagrams tab. Components are organized by assembly section including the burner, blower, and electrical groups, making it straightforward to identify parts by location in the furnace and confirm compatibility before ordering.

How often should the air filter on a Ruud UGRA-07EMAES furnace be replaced?

For most residential applications, replace the air filter every one to three months, with more frequent changes during peak heating seasons or in homes with pets. A clogged filter is one of the most common causes of high-limit switch tripping on the UGRA-07EMAES, and consistent filter replacement is the most effective preventive maintenance step for this furnace.