York TG9S080B12MP11 Parts

Shop replacement repair parts for York Furnace model TG9S080B12MP11

York TG9S080B12MP11 Parts
Brand:York
Model:TG9S080B12MP11
Product:Furnace
48 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$172.89

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$84.39

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02537499000 Flame Sensor
$71.91

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-02440901000 Blower Motor
$361.36

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/2
Voltage: 115
Full-Load Amperage: 7.7
Hertz: 60
RPM: 1175
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02649692000 Draft Inducer Motor
$273.58

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go

York TG9S080B12MP11 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common York TG9S080B12MP11 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
31 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
10 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
23 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Gas Burner
Igniter
Run Capacitor

Maintain efficient heat from your York TG9S080B12MP11 with genuine OEM replacement parts from Repair Clinic. The model decodes as an 80,000 BTU input (080) TG9S furnace, York’s 95% AFUE single-stage condensing series, in a B width cabinet with a 1,200 CFM blower class (B12) and multi-position installation (MP). The platform is shared with Coleman and Luxaire under Johnson Controls. Parts replaced most often include the TG9S080B12MP11 draft inducer motor, the gas burners, the flame sensor, and the control board. Confirm your part on the TG9S080B12MP11 parts list, then shop all York furnace parts.

TG9S080B12MP11 Platform Notes

This TG9S080B12MP11 furnace is the base MP11 build of the 80,000 BTU cabinet, with the TG9S080B12MP11A following as a later revision; boards and harnesses can differ, while most combustion parts carry across. It shares its cabinet and blower class with the 060 size, but burners, orifices, and the combustion blower restrictor are sized to the 080 input. The TG9S080B12MP11 heat exchanger has primary and secondary sections, and the secondary coil produces condensate that must drain freely. The TG9S080B12MP11 manual and TG9S080B12MP11 diagram show restrictor position and fault codes. For TG9S080B12MP11 repair steps, open the York troubleshooting page.

Most Replaced TG9S080B12MP11 Furnace Parts

Draft Inducer Motor and Restrictor

A worn inducer grinds during pre-purge and slows until the pressure switch drops out. Confirm the restrictor matches the 080 input before replacing the inducer motor, since a wrong restrictor causes the same lockouts.

Gas Burners and Uneven Flame

Rust, debris, or insects in the burner ports cause lifting or uneven flame that can trip the rollout switch or foul the flame sensor. Inspect the burners when flame looks ragged and replace damaged burners.

Flame Sensor and Igniter

A burner that lights and drops out points to the TG9S080B12MP11 flame sensor; clean it first. If draft is proven but no flame appears, inspect the TG9S080B12MP11 igniter for cracks and replace it.

Control Board and Pressure Faults

Flush the condensate trap before blaming the board for pressure faults. Replace the control board only after the code and component tests point to it, and order it for the MP11 build.

Why Choose Repair Clinic for York TG9S080B12MP11 Parts

  • Genuine York OEM Parts: Components from the platform shared with Coleman and Luxaire. Browse all York furnace parts.
  • 080 Combustion Matching: Burners, orifices, and restrictors are listed for the 80,000 BTU input.
  • Drain and Capacitor First: Flush the trap before the switch and test the run capacitor before the PSC blower motor.
  • Shop TG9S080B12MP11 Parts Online: In-stock TG9S080B12MP11 replacement parts and TG9S080B12MP11 furnace parts ship the same day with a 365-day return policy.

York TG9S080B12MP11 FAQ

What is the difference between the TG9S080B12MP11 and the MP11A?

The MP11A is a later revision of the same 80,000 BTU furnace. Combustion parts usually carry across; control boards and harnesses can differ, so match those to your suffix.

Why is my furnace not heating properly?

Read the LED code. Common causes are a fouled flame sensor, a cracked igniter, a blocked condensate drain, or dirty burners.

Can I use 060 combustion parts in this 080 furnace?

Not without checking. Burners, orifices, and the combustion blower restrictor are sized by input, so confirm every combustion part against the 080 diagram.

What are signs of a failing inducer motor?

Grinding or squealing during pre-purge, slow spin-up, and pressure switch lockouts before ignition, even with a clear condensate drain.