Lennox Central Air Conditioner CR22-41-TXV-2 Parts

Shop replacement repair parts for Lennox Central Air Conditioner model CR22-41-TXV-2

icons/central air condenser
Brand:Lennox
Model:CR22-41-TXV-2
Product:Central Air Conditioner
11 results

Lennox CR22-41-TXV-2 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Lennox CR22-41-TXV-2 problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Drain Pan
Washer kit
Seal-coil
Thermal Expansion Valve

Keep your Lennox CR22-41-TXV-2 evaporator coil system performing at its best with genuine OEM replacement parts from Repair Clinic. The CR22-41-TXV-2 is a Lennox CR-series cased evaporator coil with a factory-installed TXV for approximately three-and-a-half-ton R-410A applications. The coil is typically installed above a furnace in an upflow application or below it in a downflow application, and the N-coil or A-coil geometry allows the assembly to be slid forward out of the cabinet for cleaning and service. Repair Clinic stocks genuine Lennox OEM parts for the CR22-41-TXV-2 including the Lennox drain pan parts, Lennox TXV valve parts, and coil insulation. Browse the Lennox central air conditioner parts catalog filtered by CR22-41-TXV-2 for the complete parts inventory.

CR22-41-TXV-2: Lennox CR-Series Three-and-a-Half-Ton Cased Evaporator Coil with Factory TXV

The Lennox CR22-41-TXV-2 is specifically designated for R-410A refrigerant systems, and the factory-installed TXV is preset for R-410A operating conditions. This coil must be paired with an R-410A outdoor unit and must never be installed on an R-22 system. TXV replacement requires EPA Section 608 refrigerant handling certification because the valve is inside the refrigerant circuit.

Most Replaced Parts on the Lennox CR22-41-TXV-2

Drain Pan for the Lennox CR22-41-TXV-2

The condensate drain pan collects moisture from the coil surface during cooling operation. A drain pan that overflows continuously has a clogged condensate drain outlet rather than a cracked pan. Clear the drain line before replacing the pan to confirm the pan itself is cracked rather than simply overflowing from a downstream blockage.

TXV for the CR22-41-TXV-2

The factory-installed TXV meters refrigerant flow into the coil based on superheat at the suction service valve. A TXV stuck fully open causes a flooded coil and liquid refrigerant slugging the compressor. A TXV stuck closed causes a starved coil with no cooling capacity. TXV replacement requires EPA Section 608 refrigerant handling certification.

Coil Insulation

The coil insulation wraps refrigerant tubing connections and cabinet panels to prevent ambient moisture from condensing on cold surfaces outside the coil cabinet during cooling operation. Deteriorated or missing insulation causes moisture to accumulate on the exterior of the coil cabinet.

Distributor Assembly for the CR22-41-TXV-2

The distributor distributes refrigerant flow evenly from the TXV into the multiple parallel circuits of the coil. An uneven refrigerant distribution from a damaged distributor causes some coil circuits to operate below capacity while others operate at excess capacity.

Why Choose Repair Clinic for Lennox CR22-41-TXV-2 Parts

  • Genuine Lennox CR-Series OEM Components: Drain pans, TXV valves, and coil insulation confirmed for the CR22-41-TXV-2 three-and-a-half-ton R-410A cased coil Lennox central air conditioner parts.
  • R-410A System Specificity: The CR22-41-TXV-2 coil and its factory TXV are identified as R-410A specific in the catalog, preventing installation on R-22 systems.
  • TXV Service Requirements: EPA Section 608 refrigerant handling certification requirement for TXV replacement is noted in service guides to ensure compliance before ordering.
  • 365-Day Returns: Return any uninstalled Lennox coil part within a full year of purchase with no restocking fees.

Lennox CR22-41-TXV-2 Evaporator Coil Parts FAQ

What is the Lennox CR22-41-TXV-2 and what does the model number decode to?

The Lennox CR22-41-TXV-2 is a cased evaporator coil assembly. CR22 identifies the Lennox CR-series cased coil product line, 41 identifies the coil capacity in hundreds of BTU corresponding to approximately three-and-a-half-ton capacity, TXV indicates the coil includes a factory-installed thermostatic expansion valve, and 2 identifies the revision within the product series.

What refrigerant does the Lennox CR22-41-TXV-2 use?

The CR22-41-TXV-2 uses R-410A Puron refrigerant. Confirm the refrigerant type of the matched outdoor unit from its data plate before any refrigerant service. The TXV on this coil is preset for R-410A and must not be used with R-22 equipment.

Why is my Lennox CR22-41-TXV-2 coil icing up?

Coil icing is most commonly caused by a low refrigerant charge in the outdoor unit, restricted airflow from a clogged filter or dirty coil fins, or a blower motor not delivering adequate airflow across the coil surface. Replace the air filter before inspecting airflow and refrigerant charge.

Does the Lennox CR22-41-TXV-2 come with a factory-installed TXV?

Yes. The TXV in the model name indicates this coil includes a factory-installed thermostatic expansion valve preset for R-410A systems. The TXV is inside the refrigerant circuit and cannot be replaced without recovering the refrigerant charge first. TXV replacement requires EPA Section 608 certification.