Samsung DV42H5200EW/A3-0000 Parts

Shop replacement repair parts for Samsung Dryer model DV42H5200EW/A3-0000

icons/dryer
Brand:Samsung
Model:DV42H5200EW/A3-0000
Product:Dryer
Subtype:Electric
202 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
DC47-00019A Heating Element
$93.21

Dryer Heating element. If the dryer does not heat check for a blown thermal fuse or thermal cut out. Heating elements will often have a break in the coil element if defective.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
DC97-16782A Drum Support Roller & Axle
$59.39

Dryer drum roller assembly. Includes the roller shaft and mounting clips. As the bearing in the roller wears, it self-lubricates so no grease is needed. If the dryer is noisy then one or more of the rollers may be worn. The rollers should be replaced in sets either both front or both rear.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
6602-001655 Drive Belt
$54.94

Dryer drum drive belt. This slender belt wraps all the way around the dryer drum, around a tension pulley, and then around the drive motor pulley. If the drum will not turn when the dryer is turned on the belt is likely broken.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
DC93-00634A Idler Pulley
$61.57

Idler pulley and bracket for dryer drum belt

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
DC32-00007A Thermistor
$30.53

Dryer thermistor. If the dryer displays a fault code the thermistor may be defective.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
DC47-00016A Thermal Fuse
$31.13

Dryer thermal fuse (also called the thermal limit). Located on the blower housing. The thermal fuse blows to cut off power to the dryer if the dryer overheats. If the thermal fuse has blown, the dryer won't start. The thermal fuse cannot be reset--if the fuse has blown, it must be replaced.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
DC96-00887C Thermal Fuse
$56.94

Thermal fuse with bracket, located on the element housing. The fuse is not resettable and will need to be replaced if blown. If the dryer does not heat, the thermal fuse may be blown.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
DC97-14486A Heating Element
$263.95

Dryer heating element assembly. If the dryer no longer heats then the heating element may have failed, but it is not the most common cause. The most common cause for a dryer to stop heating is a blown thermal fuse.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
DC93-00101U Drive Motor
$368.95

Dryer drum drive motor & blower housing assembly

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
DC61-02627A Moisture Sensor
$15.12

Dryer moisture sensor. The moisture sensor monitors the clothing’s moisture level and sends a signal to the control board when the clothes are dry. If your dryer turns off too early or continues running for a while after the clothes are dry, the moisture sensor might be damaged.

Product is a manufacturer part
DC47-00015A Thermal Fuse
$36.13

Dryer thermal fuse on heater housing (non-resettable). The original thermo-protector is riveted to the mounting bracket. You will need to drill out the rivets and replace the new high limit with self-tapping screws. Item # 2074129 comes with the fuse limit already attached to the bracket.

Go

Samsung DV42H5200EW/A3-0000 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Samsung DV42H5200EW/A3-0000 problems ― and their solutions. Do any of these look familiar?
Dryer won't start
23 possible causes and potential solutions
Dryer won't start
Dryer stopped spinning
17 possible causes and potential solutions
Dryer stopped spinning
Dryer drum not turning
13 possible causes and potential solutions
Dryer drum not turning

Frequently Purchased Together For This Model

Heating Element
Drum Support Roller & Axle
Drive Belt
Idler Pulley

Keep your Samsung DV42H5200EW/A3-0000 electric dryer running reliably with genuine OEM replacement parts from Repair Clinic. The DV42H5200EW/A3-0000 is a 7.4 cubic foot residential electric dryer from Samsung. The A3 identifies the color variant and 0000 identifies the production suffix. The thermal fuse, heating element, and drive belt account for the majority of service calls. The thermal fuse is a one-time safety device and a blown fuse is almost always caused by a restricted exhaust duct. Repair Clinic stocks genuine Samsung OEM parts for the DV42H5200EW/A3-0000 including the Samsung dryer thermal fuse parts, Samsung dryer heating element parts, Samsung dryer belt parts, and Samsung dryer control board parts. Browse the Samsung dryer parts catalog filtered by DV42H5200EW/A3 for the complete parts inventory.

DV42H5200EW/A3-0000: Samsung 7.4 Cubic Foot Electric Dryer Service

The Samsung DV42H5200EW/A3-0000 uses a wrapped-coil heating element and a thermal fuse on the blower housing that interrupts the heating circuit if exhaust air temperature exceeds a safe threshold from a restricted duct. This fuse cannot be reset and must be replaced after the exhaust restriction is fully cleared. Clearing the exhaust duct before installing the replacement fuse is mandatory to prevent immediate recurrence. The dryer repair help section covers DV42H5200EW/A3 thermal fuse access, heating element replacement, and exhaust duct inspection.

Most Replaced Parts on the Samsung DV42H5200EW/A3-0000

Thermal Fuse for the Samsung DV42H5200EW/A3

The thermal fuse blows when the exhaust air temperature exceeds a safe threshold from a restricted or kinked exhaust duct. Inspect and clear the exhaust duct completely before installing the replacement fuse. A duct that is kinked, clogged with lint, or improperly sized will blow the replacement fuse immediately under the same conditions that caused the original failure.

Heating Element for the DV42H5200EW/A3

An element that tests open-circuit with a multimeter must be replaced. Before replacing the heating element, test the thermal fuse for continuity. A blown thermal fuse prevents the element from energizing even when the element itself is intact.

Drive Belt for the Samsung DV42H5200EW/A3

The drive belt wraps around the drum and connects to the idler pulley and motor shaft. A broken belt causes the drum to stop rotating while the motor continues to run. When replacing the drive belt, inspect the idler pulley tension spring and drum glides for wear.

Control Board for the DV42H5200EW/A3

A control board fault typically presents as persistent error codes that remain after the underlying component has been repaired, or as cycles that do not advance normally despite functioning heating and drum rotation.

Why Choose Repair Clinic for Samsung DV42H5200EW/A3-0000 Parts

  • Genuine Samsung OEM Components: Thermal fuses, heating elements, and drive belts confirmed for the DV42H5200EW/A3-0000 7.4 cubic foot electric dryer Samsung dryer parts.
  • Thermal Fuse Root Cause Guidance: Exhaust duct inspection and clearance before thermal fuse replacement is documented in Repair Clinic service guides to prevent immediate recurrence.
  • Electric Dryer Repair Resources: Thermal fuse access, heating element testing, and exhaust duct inspection through dryer repair help.
  • 365-Day Returns: Return any uninstalled Samsung part within a full year of purchase with no restocking fees.

Samsung DV42H5200EW/A3-0000 Electric Dryer Parts FAQ

What is the Samsung DV42H5200EW/A3-0000 and what does the model notation mean?

The DV42H5200EW/A3-0000 is a 7.4 cubic foot Samsung electric dryer. DV42H5200EW identifies the product series, A3 identifies the color variant, and 0000 identifies the production suffix.

Why is my Samsung DV42H5200EW/A3 not heating?

No heat is most commonly caused by a blown thermal fuse from a restricted exhaust duct. Inspect and fully clear the exhaust duct before installing the replacement fuse or it will blow immediately.

How do I test the heating element on the Samsung DV42H5200EW/A3?

Disconnect power and remove the rear panel. Disconnect the element wires and test resistance across the terminals with a multimeter. An infinite reading means the element is open-circuit and must be replaced.

What is the most common cause of thermal fuse failure on the DV42H5200EW/A3?

A restricted, kinked, or clogged exhaust duct is the most common cause. The duct must be fully cleared before installing the replacement fuse.