Keep your GSX130241EE central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The GSX130241EE is a two-ton, 13 SEER R-410A residential outdoor condensing unit. The unit uses R-410A Puron refrigerant. The 024 identifies 24,000 BTU two-ton capacity and EE identifies the production configuration within the GSX130241 series. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Goodman OEM parts for the GSX130241EE including the Goodman capacitor parts, Goodman contactor parts, Goodman fan motor parts, and Goodman high-pressure switch parts. Browse the Goodman central air conditioner parts catalog filtered by GSX130241EE for the complete parts inventory.
GSX130241EE: Two-Ton, 13 Seer R-410A Outdoor Condensing Unit Service
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the GSX130241EE. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
Most Replaced Parts on the GSX130241EE
Dual Run Capacitor for the GSX130241EE
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor in a single can. A capacitor reading more than 10% below its rated microfarad value causes the compressor to hard-start, accumulating heat in the motor windings. Match all three microfarad values from the installed capacitor label before ordering.
GSX130241EE Contactor
The contactor closes the 240-volt compressor power circuit at every cooling cycle start. Pitted or burned contact surfaces generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
Outdoor Fan Motor for the GSX130241EE
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
High-Pressure Switch for the GSX130241EE
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
Why Choose Repair Clinic for GSX130241EE Parts
- Genuine Goodman GSX13 OEM Components: Two-ton dual run capacitors, contactors, and fan motors confirmed for the GSX130241EE EE configuration Goodman central air conditioner parts.
- R-410A Puron Platform: The GSX130241EE uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
- Annual Capacitor Testing Priority: Pre-season capacitance testing is documented as the most cost-effective preventive maintenance step for the GSX130241EE.
- 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.
GSX130241EE Parts FAQ
What is the GSX130241EE and what ton size is it?
The GSX130241EE is a two-ton, 13 SEER R-410A residential outdoor condensing unit from Goodman’s GSX13 series. The unit uses R-410A Puron refrigerant.
Why does my GSX130241EE hum but not start?
A unit that hums but does not start has most commonly failed at the dual run capacitor, which cannot provide adequate starting torque to the compressor or fan motor. Test the capacitor with a digital capacitance meter before testing any other component.
How does the Goodman GSX130241EE differ from the GSX130301BA?
The GSX130241EE is a two-ton unit while the GSX130301BA is a two-and-a-half-ton unit on the same GSX13 13 SEER R-410A platform. The dual run capacitor carries different compressor-section microfarad ratings between the two tonnages. Never substitute capacitor specifications between the 024 and 030 configurations.
How often should I test the capacitor on the GSX130241EE?
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.