Shop replacement repair parts for Kenmore Dryer model 11072992100

Dryer gas burner valve solenoid set. If the dryer does not heat or heats intermittently the coils could be defective. To test, watch the burner and if the igniter glows for a while and then shuts off without the gas igniting, it usually means one of these coils is bad.

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

The Whirlpool Burner Igniter Kit 279311 is a high-quality replacement part that ignites gas to light the dryer burner. It replaces multiple igniters and requires safety precautions and disconnection from utilities before installation.

Dryer thermal fuse (or thermal limiter). This fuse is located on the exhaust duct. If the dryer overheats, the thermal fuse opens to cut off power to the dryer. The thermal fuse cannot be reset--if the thermal fuse is open, it must be replaced.

Drive motor kit - Note; the wiring connections may be different, comes with instructions

Replacement dryer gas valve & burner kit

Dryer Timer, 60 Hz. WP8299771

Harns-wire

Harns-wire

Replacement dryer gas valve assembly

Harns-wire

Wire harness, gas valve

Control Board