Shop replacement repair parts for Kenmore Dryer model 11077542600

Dryer gas burner valve solenoid set. If the dryer does not heat or heats intermittently the coils could be defective. To test, watch the burner and if the igniter glows for a while and then shuts off without the gas igniting, it usually means one of these coils is bad.

The Whirlpool Burner Igniter Kit 279311 is a high-quality replacement part that ignites gas to light the dryer burner. It replaces multiple igniters and requires safety precautions and disconnection from utilities before installation.

Gas dryer sensor for igniter and flame. The sensor is located across from the gas igniter at the dryer’s burner assembly. This flame sensor should be closed for continuity at room temperature. Check for continuity with a multi-meter before replacing.

Gas valve assembly without burner tube

Harness, wiring