Goodman Central Air Conditioner GSX130241FA Parts

Shop replacement repair parts for Goodman Central Air Conditioner model GSX130241FA

icons/central air condenser
Brand:Goodman
Model:GSX130241FA
Product:Central Air Conditioner
6 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
CONT2P030024DS Contactor
$36.32

Contactor, 2 pole, 30 amp, 24 vac **Special Note** This may replace single pole contactor and require a technican to install (based on model #)

Goodman GSX130241FA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman GSX130241FA problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Dual Run Capacitor
Contactor
Blower Motor
Service Valve

Ensure your GSX130241FA central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The GSX130241FA is a two-ton, 13 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The 024 identifies two-ton capacity and FA identifies the production configuration within the GSX130241 series. Goodman, Daikin, and Amana are related brands under the same parent company. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Goodman OEM parts for the GSX130241FA including the Goodman capacitor parts, Goodman contactor parts, Goodman fan motor parts, and Goodman high-pressure switch parts. Browse the Goodman central air conditioner parts catalog filtered by GSX130241FA for the complete parts inventory.

GSX130241FA: Two-Ton, 13 Seer R-410A Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the GSX130241FA. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the GSX130241FA

Dual Run Capacitor for the GSX130241FA

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

GSX130241FA Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the GSX130241FA

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the GSX130241FA

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for GSX130241FA Parts

  • Genuine Goodman GSX13 OEM Components: Two-ton dual run capacitors, contactors, and fan motors confirmed for the GSX130241FA configuration Goodman central air conditioner parts.
  • R-410A Puron Platform: The GSX130241FA uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the GSX130241FA.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

GSX130241FA Parts FAQ

What is the GSX130241FA and what ton size is it?

The GSX130241FA is a two-ton, 13 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The 024 identifies two-ton capacity and FA identifies the production configuration within the GSX130241 series. Goodman, Daikin, and Amana are related brands under the same parent company.

Why does my GSX130241FA hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

How does the Goodman GSX130241FA differ from the GSX130301BC?

The GSX130241FA is a two-ton unit while the GSX130301BC is a two-and-a-half-ton unit on the same Goodman GSX13 13 SEER R-410A platform. The dual run capacitor carries different compressor-section microfarad ratings between the two tonnages.

How often should I test the capacitor on the GSX130241FA?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.