Bradford White RG250T6N Parts

Shop replacement repair parts for Bradford White Water Heater model RG250T6N

icons/water heater
Brand:Bradford White
Model:RG250T6N
Product:Water Heater
21 results
Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
415-51230-18 Dip Tube
$70.45

Dip tube with 2 inch nipple, 40-1/2 inches long

Go

Bradford White RG250T6N Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Bradford White RG250T6N problems ― and their solutions. Do any of these look familiar?
Water heater not heating
6 possible causes and potential solutions
Water heater not heating
Water heater leaking
4 possible causes and potential solutions
Water heater leaking
Water heater not lighting
6 possible causes and potential solutions
Water heater not lighting

Frequently Purchased Together For This Model

Pilot
Anode Rod
Outer Door Panel
Temperature and Pressure Relief Valve

Restore steady hot water from your Bradford White RG250T6N with genuine OEM replacement parts from Repair Clinic. The model identifies a 50-gallon (50), tall tank (T), natural gas (N) atmospheric water heater in Bradford White’s RG2 residential line. Parts replaced most often include the thermocouple and pilot assembly, the gas valve, the RG250T6N anode rod, and the dip tube. Locate each part on the RG250T6N parts list, then browse all Bradford White water heater parts.

How the RG250T6N Water Heater Is Built

This is a gas model, so there is no electric RG250T6N heating element; the main burner under the tank heats the water. The RG250T6N thermostat is built into the gas control valve, so a thermostat that will not regulate is solved by replacing the valve assembly. If your unit has Bradford White’s Defender FVIR system, a flame arrestor and thermal shutoff can stop the burner when the air intake is blocked, so clean the intake before replacing safety parts. The RG250T6N manual and RG250T6N diagram show lighting steps and part positions. For RG250T6N repair steps, visit the water heater troubleshooting page.

Most Replaced RG250T6N Parts

Thermocouple and Pilot

If the pilot lights but goes out when you release the button, the thermocouple is the first suspect. Test it before the gas valve. If a new thermocouple does not hold the pilot, check the orifice and replace the pilot assembly.

Gas Valve and Thermostat

Replace the gas valve when the thermocouple tests good, the intake is clean, and the valve still will not hold the pilot or keep the set temperature.

Anode Rod

The sacrificial anode rod corrodes so the tank does not. Inspect it every two to five years, sooner with hard or softened water, and replace it when the core wire shows. Order a matching anode rod.

Dip Tube

A cracked RG250T6N dip tube lets cold inlet water mix at the top of the 50-gallon tank, so hot water runs out quickly. Plastic flakes in faucet aerators confirm it. Replacements are listed under tubes and fittings.

Why Choose Repair Clinic for Bradford White RG250T6N Parts

  • Genuine Bradford White Parts: OEM RG250T6N parts built to factory specifications. Shop all Bradford White water heater parts.
  • Gas Model Clarity: No electric element and no separate thermostat; the burner and gas control valve handle both jobs.
  • Thermocouple Before Valve: Test the thermocouple and clean the intake before replacing the gas valve.
  • Shop RG250T6N Parts Online: In-stock RG250T6N replacement parts and RG250T6N water heater parts ship the same day with a 365-day return policy.

RG250T6N Water Heater FAQ

How often should I check the anode rod?

Every two to five years, sooner in hard or softened water. Replace it when the core wire is exposed or it has lost half its diameter.

Why is my RG250T6N not heating properly?

Check the pilot first. A weak thermocouple, a failing gas valve, or a dirty burner are the common causes, tested in that order.

Does this water heater have a heating element?

No. It is a natural gas model, so the burner heats the tank and the thermostat is part of the gas control valve.

Why does my hot water run out fast?

A broken dip tube or heavy sediment can cut usable capacity. Plastic pieces in faucet aerators point to the dip tube.