Shop replacement repair parts for Kenmore Dryer model 110.86572500

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer idler pulley assembly. Includes bracket and pulley wheel

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Dryer heating element. If the dryer no longer heats then the heating element may have failed, but it is not the most common cause. The most common cause for a dryer to stop heating is a blown thermal fuse.

High limit thermostat, L295-50F. If the dryer overheats, this high-limit thermostat will cut off the power to the heating element. If the high-limit thermostat has blown, the dryer will not heat.

Dryer door switch & harness assembly

Knob