Shop replacement repair parts for Kenmore Dryer model 110.85088401

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer heating element assembly. If the dryer does not heat the thermal fuse should be checked before replacing the heating element. Normally, the element will have a break in the coil if defective.

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

High limit thermostat, L295-50F. If the dryer overheats, this high-limit thermostat will cut off the power to the heating element. If the high-limit thermostat has blown, the dryer will not heat.

Harness, sensor

Digital interface wire harness

Main wire harness with power cord terminal block

Main Control Board