Shop replacement repair parts for Maytag Dryer model MEDE400XW0

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Dryer high limit thermostat and thermal fuse kit. If the dryer does not heat the most common cause is a blown thermal fuse. Both the thermostat and fuse can be tested to determine if either is defective.352 F fuse. L146.1-44.4c thermostat.

Dryer heating element. If the dryer no longer heats then the heating element may have failed, but it is not the most common cause. The most common cause for a dryer to stop heating is a blown thermal fuse.

Drive motor kit - Note; the wiring connections may be different, comes with instructions

High limit thermostat, L295-50F. If the dryer overheats, this high-limit thermostat will cut off the power to the heating element. If the high-limit thermostat has blown, the dryer will not heat.

Harness, sensor

Harns-wire

Harns-wire

Harns-wire

Electronic Control

Dryer electronic main control board. The control board regulates the dryer's main functions. Control boards are frequently misdiagnosed. Be sure to check more commonly defective parts before replacing the control board.