Shop replacement repair parts for Maytag Dryer model MED7000XR0

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Dryer heating element. If the dryer no longer heats then the heating element may have failed, but it is not the most common cause. The most common cause for a dryer to stop heating is a blown thermal fuse.

Thermal cut out fuse and high limit thermostat kit

Hi-limit thermostat & thermistor assembly on heating element housing, L295-80F Thermistor should read around 50 to 60Kohms at room temperature.

Wire harness

Drive Motor

Electronic Control Board

Harns-wire

Harns-wire

Harns-wire

Harns-wire

Control board kit