Shop replacement repair parts for Maytag Dryer model MEDB850WB0

Dryer drum support roller. If the dryer is making a rumbling or knocking noise the rollers may be worn out causing the drum not to turn smoothly.

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Dryness sensor bar

Dryer high limit thermostat and thermal fuse kit. If the dryer does not heat the most common cause is a blown thermal fuse. Both the thermostat and fuse can be tested to determine if either is defective.352 F fuse. L146.1-44.4c thermostat.

Dryer lint filter. Air flow is vital to proper dryer operation. The lint filter should be cleaned before every load and replaced if damaged.

Dryer heating element. If the dryer no longer heats then the heating element may have failed, but it is not the most common cause. The most common cause for a dryer to stop heating is a blown thermal fuse.

Plastic leveling leg. White approximately 1" round x 1 3/4" long

Dryer heating element wire connector kit. Wire with spade terminal & wire nut

Dryer tri-ring retainer for drum support rollers.

Light Bulb 10 Watt small base

Dryer door catch. If the dryer door does not latch closed then the door strike or this catch is likely damaged

Dryer idler wheel and bracket assembly. Provides tension to the dryer drum belt.

Dryer thermal fuse (or thermal limiter). This fuse is located on the exhaust duct. If the dryer overheats, the thermal fuse opens to cut off power to the dryer. The thermal fuse cannot be reset--if the thermal fuse is open, it must be replaced.