Video & Articles: Appliance & Equipment RepairSkuttle Humidifier Filter Drum Replacement #A01-1722-018

Skuttle Humidifier Filter Drum Replacement #A01-1722-018

01:57
This video provides step-by-step repair instructions for replacing the filter drum (or filter frame) on a Skuttle humidifier. The most common reason for replacing the humidifier filter drum is when it is damaged.

All of the information for this filter drum replacement video is applicable to the following brands:
Skuttle

Step By Step Instructions

1
To install the drum and filter kit in your humidifier first turn off the power to the furnace.
2
Push the humidifier cover down to release the tabs then pull the cover off.
3
Next, pull the duct side of the drum shaft out of the bushing to remove the old filter assembly.
4
Prepare the new drum and filter kit for installation by inserting the shaft through the closed drum frame until it is fully seated in the frame.
5
Slide on the spring retainer.
6
Align the filter on the closed drum frame and slide the open drum frame onto the shaft.
7
Secure it with the second spring retainer.
8
Install the filter assembly by inserting the drive side of the shaft into the motor bushing then snap the opposite end of the shaft into the duct bushing.
9
Replace the cover by inserting the tabs into the slots in the housing then lower the cover and pull it into position.
10
You’re now ready to restore power to the furnace and confirm that the humidifier is working properly.
Description
This video provides step-by-step repair instructions for replacing the filter drum (or filter frame) on a Skuttle humidifier. The most common reason for replacing the humidifier filter drum is when it is damaged.

All of the information for this filter drum replacement video is applicable to the following brands:
Skuttle
Step-By-Step Instructions
1
To install the drum and filter kit in your humidifier first turn off the power to the furnace.
2
Push the humidifier cover down to release the tabs then pull the cover off.
3
Next, pull the duct side of the drum shaft out of the bushing to remove the old filter assembly.
4
Prepare the new drum and filter kit for installation by inserting the shaft through the closed drum frame until it is fully seated in the frame.
5
Slide on the spring retainer.
6
Align the filter on the closed drum frame and slide the open drum frame onto the shaft.
7
Secure it with the second spring retainer.
8
Install the filter assembly by inserting the drive side of the shaft into the motor bushing then snap the opposite end of the shaft into the duct bushing.
9
Replace the cover by inserting the tabs into the slots in the housing then lower the cover and pull it into position.
10
You’re now ready to restore power to the furnace and confirm that the humidifier is working properly.

Applicable Product Model

Related Articles & Videos

01:54
Part Replacement
Skuttle Humidifier Water Pan Replacement #A00-0602-039
02:27
Part Replacement
Skuttle Humidifier Float Assembly Replacement #A17-1731-013
02:18
Part Replacement
Skuttle Humidifier Drive Motor Replacement #A05-1721-042
01:55
Part Replacement
Skuttle Humidifier Replace Water Evaporator Pad #A04-1725-033