DescriptionThis video provides step-by-step instructions for replacing the circulation pump on GE dishwashers. The most common reasons for replacing the pump are when the dishwasher doesn’t clean or makes noise.
All of the information in this circulation pump replacement video is applicable to the following brands: GE
Tools used: 1/4” socket or nut driver, channel-lock pliers, 5/16” socket or nut driver, pliers, small flat-head screwdriver
Step-By-Step Instructions1
To replace the circulation pump on your dishwasher, you will need to uninstall the appliance first. To do this, turn off the power to your dishwasher
2
Shut off the water supply valve.
3
Use a quarter-inch socket or nut driver to remove the screws securing the lower access panel.
4
Remove the panel along with any insulation.
5
Use channel –lock pliers to help unthread the water supply line fitting from the inlet valve be prepared for some water to spill.
6
Next, use a 5/16th inch socket or nut driver to unthread the screw securing the junction box cover. Then pull the cover off.
7
Note the location of the wires then untwist the wire nuts to disconnect the wires.
8
Unthread the strain relief nut and detach the strain relief from the junction box.
9
Next, disconnect the drain hose from the sink or garbage disposer and feed it through the cabinet.
10
Open the dishwasher door and remove the mounting bracket screws.
11
To move the dishwasher, you may need to adjust the legs to lower the appliance.
12
Now, to avoid damage, very carefully pull the dishwasher away from the cabinet.
13
Remove the insulating blanket then tip the dishwasher back so it rests on its back panel.
14
Now unthread the screws securing the drip tray.
16
Use pliers to help break off the retaining clamps securing the incoming and outgoing water hoses to the circulation pump.
17
With the clamps removed, detach the pump from the base and pull it free of the hoses.
18
Remove the cover and disconnect the wire connecter.
19
You’re now ready to install the new circulation pump.
20
Connect the wire connecter to the new pump and align the cover.
21
You can use a small flat-head screwdriver to help lock the cover tabs in place.
22
Position the provided clamps on the hoses.
23
Attach the incoming and outgoing hoses to the appropriate ports on the new pump as you insert the pump hanger into the sump base.
24
Position the clamps and tighten the screws to secure.
25
Reposition the drip tray and secure it with the screws.
26
Return the dishwasher to its upright position and realign the insulating blanket.
27
Make sure the end of the drain hose is accessible through the cabinet wall then gently slide the dishwasher back into the cabinet.
28
Adjust the leveling legs if necessary.
29
Replace the screws to secure the mounting brackets to the cabinet or countertop.
30
Feed the drain hose through the cabinet and connect it to the sink drain or disposer.
31
Make sure the hose is elevated above the connection point.
32
Fully position the wire strain relief in the junction box and secure the strain relief nut.
33
Connect the wires using the wire nuts.
34
Align the cover and replace the screw to secure.
35
Reconnect the water supply line to the inlet valve.
36
Replace any insulation then reposition the lower access panel.
37
Secure it with the screws.
38
With the repair completed, turn the water supply back on as well as the power and your dishwasher should be ready for use.