Video & Articles: Appliance & Equipment RepairFrigidaire Microwave Oven Door Monitor Switch Replacement 22001930

Frigidaire Microwave Oven Door Monitor Switch Replacement 22001930

05:00
This video provides step-by-step repair instructions for replacing the door monitor switch on a Frigidaire microwave oven (Model FPMO227NUFA). The most common reason for replacing this part is if the microwave is not working at all.

All of the information for this video is applicable to the following brands:
Frigidaire

Step By Step Instructions

1
Frigidaire Microwave Oven - FPMO227NUFA
2
Frigidaire Microwave Oven Door Monitor Switch Replacement
3
Tools needed: T-15 tamper-proof Torx bit, Phillips-head screwdriver, small flat-head screwdriver, needle-nose pliers
4
Shock
5
Because of the high voltage and high current used by microwave ovens, be aware that repairing this appliance poses a substantial risk for injury or death if precautions are not taken.
6
You should always unplug the microwave before you attempt any disassembly.
7
Since high voltage capacitors used in microwaves may retain a charge even after the microwave has been unplugged, we recommend that only experienced professionals access and replace internal components.
8
Unthread the six rear screws securing the cover using the T-15 tamper-proof Torx bit.
9
Unthread the screw on the right side of the cover as well.
10
Sharp
11
Pull the rear sides of the cover out then lift the cover up and pull back to fully remove.
12
Shock
13
You should release the potentially stored electrical charge in the capacitor to avoid injury.
14
You can do this by placing needle-nose pliers with an insulated handle across each set of terminals.
15
Using the Phillips-head screwdriver, unthread the screw securing the control panel.
16
Open the door and lift the control panel up to detach.
17
Note the orientation of the wires on the door switch, then use the small flat-head screwdriver to depress the locking tabs to detach the wires from the terminals.
18
Release the door latch bracket retaining tabs and pull the old switch free.
19
To install the new door monitor switch, align it in the bracket and snap it into place.
20
Connect the wires to the appropriate terminals.
21
Making sure the door release lever is positioned under the latch lever, insert the lower tabs of the control panel into the slots in the frame, then thread the screw to secure the panel.
22
Reinstall the microwave oven cover by first aligning the top edge then the sides.
23
Thread and tighten the seven screws to secure.
24
Plug the power cord back in and the microwave oven should be ready for use.
Description
This video provides step-by-step repair instructions for replacing the door monitor switch on a Frigidaire microwave oven (Model FPMO227NUFA). The most common reason for replacing this part is if the microwave is not working at all.

All of the information for this video is applicable to the following brands:
Frigidaire
Step-By-Step Instructions
1
Frigidaire Microwave Oven - FPMO227NUFA
2
Frigidaire Microwave Oven Door Monitor Switch Replacement
3
Tools needed: T-15 tamper-proof Torx bit, Phillips-head screwdriver, small flat-head screwdriver, needle-nose pliers
4
Shock
5
Because of the high voltage and high current used by microwave ovens, be aware that repairing this appliance poses a substantial risk for injury or death if precautions are not taken.
6
You should always unplug the microwave before you attempt any disassembly.
7
Since high voltage capacitors used in microwaves may retain a charge even after the microwave has been unplugged, we recommend that only experienced professionals access and replace internal components.
8
Unthread the six rear screws securing the cover using the T-15 tamper-proof Torx bit.
9
Unthread the screw on the right side of the cover as well.
10
Sharp
11
Pull the rear sides of the cover out then lift the cover up and pull back to fully remove.
12
Shock
13
You should release the potentially stored electrical charge in the capacitor to avoid injury.
14
You can do this by placing needle-nose pliers with an insulated handle across each set of terminals.
15
Using the Phillips-head screwdriver, unthread the screw securing the control panel.
16
Open the door and lift the control panel up to detach.
17
Note the orientation of the wires on the door switch, then use the small flat-head screwdriver to depress the locking tabs to detach the wires from the terminals.
18
Release the door latch bracket retaining tabs and pull the old switch free.
19
To install the new door monitor switch, align it in the bracket and snap it into place.
20
Connect the wires to the appropriate terminals.
21
Making sure the door release lever is positioned under the latch lever, insert the lower tabs of the control panel into the slots in the frame, then thread the screw to secure the panel.
22
Reinstall the microwave oven cover by first aligning the top edge then the sides.
23
Thread and tighten the seven screws to secure.
24
Plug the power cord back in and the microwave oven should be ready for use.

Applicable Product Model

icons/microwave
Brand
Product Type
Model
Subtype
Product Diagram & Manuals
Parts Needed
Switch
Switch
$36.45
Total$0.00

Related Articles & Videos

04:41
Part Replacement
Frigidaire Microwave Oven Control Panel Assembly Replacement 5304519365
05:18
Part Replacement
Frigidaire Microwave Oven Door Release Push Button Replacement 5304519323
03:56
Part Replacement
Frigidaire Microwave Oven Lamp Assembly Replacement 5304519338
06:46
Part Replacement
Frigidaire Microwave Oven Door Interlock Switch Replacement 5304515182
05:26
Part Replacement
Frigidaire Microwave Oven Door Release Push Button Spring Replacement 5304519324