DescriptionThis video provides step-by-step repair instructions for replacing the 4-wire terminal blocks on a Frigidaire Range Vent Hood (model FHWC3660LSA). The most common reason for replacing this part is if one or more functions on the vent hood do not work.
All of the information for this part replacement video is applicable to the following brands:
Frigidaire
Step-By-Step Instructions1
Frigidaire Range Vent Hood - FHWC3660LSA
2
Frigidaire Range Vent Hood Four-Wire Terminal Block Replacement
3
Tools needed: Phillips-head screwdriver, small flat-head screwdriver
5
Before you begin the procedure, be sure to turn off the power supply to the hood.
6
Pull the right-side lever down to release the grease filter.
7
Use the Phillips-head screwdriver to unthread the four screws to release the terminal block cover.
8
Note the orientation of the wires attached to the four-wire terminal block, then use the small flat-head screwdriver to loosen the screws to release the wires.
9
To install the new four-wire terminal block, insert the wires into the appropriate terminals and tighten the screws to secure.
10
Position the terminas blocks in the housing then align the cover.
11
Thread the screws to secure the cover.
12
Reinstall the grease filter by aligning the left side tabs with the slots in the hood, then pull the lever to align the right side.
13
Turn the power supply back on and the range vent hood should be ready for use.