Description
This video provides step-by-step repair instructions for replacing the dual harness connector bracket in a GE washer (Model GTW465ASN2WW). The most common reason for replacing this part is if it's missing or broken.
This replacement video is applicable to the following brands:
GE
Screws affiliated with washer-
Don't forget to like and comment on this video and subscribe to our channel!
Step-By-Step Instructions1
To replace the dual harness connector bracket in your ge washer, you will need an impact driver with a 1/4” bit, pliers, a 3/8” socket, needlenose pliers, and a 1/4” socket adapter.
2
Before you begin the procedure, unplug the power to the washer.
3
Shut off the water supply
4
Remove the drain line from the wall
5
Remove the hot and cold-water supply lines from the inlet valve.
6
Prop up the washer. you can use a wooden block or chair.
7
Unthread the three screws on the protective belt cover to remove it.
8
Unplug the drain pump and mode shifter.
9
Squeeze the tabs with the pliers to detatch the wire connectors.
10
Unthread the screw that secures the bracket then pull and slide it out from the transmission.
11
To install the new dual harness connector bracket, slide the bracket tabs into the slots and then rethread the screw to secure.
12
Snap the connectors into the bracket.
13
Plug in the drain pump and mode shifter.
14
Align the cover and start one of the three screws.
15
Place the grounding connector over the screw and rethread it to the bottom of the transmission.
16
Now rethread the last screw.
18
Reattach the hot and cold-water supply lines.
19
Insert the drain hose back into the wall drain.
20
Turn on the water supply