Carrier Central air conditioner is noisy or loud

If your Carrier central AC is making loud noise, the outdoor condensing unit usually has a mechanical problem that you can locate by listening and inspecting. First, shut off power at the disconnect box and circuit breaker, then check for debris hitting the condenser fan blade, the most common cause of an air conditioner making noise. Next, inspect the condenser fan motor, since worn bearings can cause AC fan motor noise; with power off, the motor shaft should rotate smoothly by hand. Loose grille or cabinet panels can also vibrate and create rattling. If the motor shaft is loose, inspect the condenser fan blade and tighten its set screw or replace the blade if it is damaged or unbalanced. A failing condenser fan motor can produce similar noise, especially when its bearings wear out. Less commonly, a defective contactor can make buzzing or chattering sounds and may prevent the condensing unit from cooling. Inspecting or replacing parts around 240V components requires care, and contactor testing or electrical repair is best left to a qualified HVAC technician. Enter your Carrier model number to find the exact replacement fan motor, fan blade, or contactor for your central air conditioner.

01 - Debris Hitting Fan

Over time debris can fall into the condensing unit, causing a noise when the fan is running. Inspect the fan blade and inside the unit for any debris. Clean out the outdoor unit as needed but be sure to shut off power to the unit before attempting to clean it out.
Top Solution

02 - Carrier Central Air Conditioner Fan Motor

The fan motor has bearings that can wear out over time. When the bearings are worn out, they make loud noise. To check the bearings, try rotating the fan motor by hand. If the motor does not turn smoothly, replace it.
Enter model number to search for the required part specific to your product
Highly Likely

03 - Panels Vibrating

If the outdoor condensing unit is noisy, the grille or one of the panels may be loose and vibrating. Check for loose panels and tighten them as needed.
Highly Likely

04 - Carrier Central Air Conditioner Fan Blade

The fan blade on the condenser fan motor might be defective or loose. To check the fan blade, wiggle the fan motor shaft. If the motor shaft is loose, tighten or replace the set screw. If the condenser fan motor is still making noise, replace the fan blade.
Less Common

05 - Carrier Central Air Conditioner Condenser Fan Motor

The condenser fan motor has bearings that can wear out over time. When the bearings are worn out, they make loud noise. To check the bearings, try rotating the condenser fan motor by hand. If the motor does not turn smoothly, replace it.
Less Common

06 - Carrier Central Air Conditioner Contactor

The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. In addition, the contactor will make noise when it is defective. If the condensing unit is making noise but not cooling, the contactor has probably failed. To determine if the contactor is at fault, use a multimeter to test the contactor for continuity. If the contactor does not have continuity, replace it.
Less Common

Frequently Asked Questions

Why is my Carrier central air conditioner making a loud noise?
What should I check if the condenser fan is making noise?
Why is my Carrier AC making a buzzing noise but not cooling?
How do I know whether the noisy condenser fan motor or fan blade is defective?
How can I find the correct Carrier condenser fan motor or fan blade replacement part?

Shop by Carrier Central Air Conditioner Parts