HomePartsNordyne PartsNordyne Furnace PartsNordyne Furnace Igniter Parts

Nordyne Furnace Igniter Parts

Order genuine OEM Nordyne Furnace Igniter Parts built for dependable starts when your furnace clicks but won't light. Match the right igniter to your model, then order with same-day shipping, a price match guarantee, 365-day returns, and expert repair guidance.

Find the right part faster

Multiple models matched. Select your model to confirm fit.

7 results for 
Nordyne
Igniter
Furnace
Sort:
Find. Fix. Finish.
Whether you're a pro or a novice, we've got you covered with the repair know-how and replacement Nordyne Furnace parts you need.
Genuine OEM Parts Supplier
Genuine OEM Nordyne Replacement Parts
Get peace of mind with the real thing—genuine OEM Nordyne Furnace parts.
365-Day Appliance Parts Return Policy
No-Hassle 365-Day Returns
Return uninstalled Nordyne Furnace parts and products for any reason within 365 days of purchase.
Same day shipping
Same-Day Shipping
Get the job finished. Order replacement Nordyne Furnace parts by 9:00 PM ET, and we'll ship them the same day.
Price Match Guarantee For Appliance Parts
Price Match Guarantee
We'll match any price offered by our direct competitors on all genuine OEM Nordyne Furnace replacement parts
Genuine OEM Parts Supplier
Genuine OEM Nordyne Replacement Parts
Get peace of mind with the real thing—genuine OEM Nordyne Furnace parts.

Nordyne Furnace Igniter Parts

The hot surface igniter is the hardest-working part in your Nordyne furnace. When it glows orange and opens the gas valve, your heating cycle begins — and when it fails, nothing happens. Nordyne furnaces (including Intertherm, Miller, and Gibson brands) rely on a ceramic igniter that heats to over 1800°F in seconds. If your furnace clicks but won't ignite, or you see an orange glow that fades before gas flows, the igniter has likely weakened or cracked.

Nordyne igniters come in two types: silicon carbide (SiC) and silicon nitride (SiN). Your model number determines which one fits — using the wrong type means the furnace won't start, even though the part looks identical. Order the correct igniter, verify the ohm rating matches your original, and your heating should come back on within minutes.

  • Igniter glows orange but goes out before gas flows: ceramic element is weak; replace it
  • Igniter doesn't glow at all: cracked element or open circuit; OEM igniter required
  • Furnace clicks rapidly then stops: weak igniter trips the safety lockout; igniter replacement fixes it
  • Igniter glows but is dim or dull red: element aging; replacement will restore bright orange glow and faster ignition
  • Igniter sparks or pops: ceramic fracture; replace immediately to prevent secondary damage

Nordyne Furnace Igniter: Frequently Asked Questions

How do I know if my Nordyne furnace igniter has failed?

A failing Nordyne igniter usually shows itself in one of two ways: either it glows but the furnace doesn't light (gas valve won't open because igniter is too weak), or it doesn't glow at all (element is cracked or the circuit is open). You may also hear the furnace clicking repeatedly as the control board detects no flame and shuts down the ignition cycle. If you see any orange glow at all, the igniter is in its final hours — replace it before it goes completely dead.

What's the difference between SiC and SiN igniters for Nordyne furnaces?

Silicon carbide (SiC) and silicon nitride (SiN) igniters are NOT interchangeable, even though they look similar. Your Nordyne model number determines which type your furnace requires. SiC igniters are older and more common in Intertherm and Miller furnaces; SiN igniters are found in newer, higher-efficiency Nordyne models. Using the wrong type will result in a furnace that won't ignite, so always verify your model number before ordering. Repair Clinic's model lookup will confirm the correct igniter type and part number for you.

Can I clean my Nordyne igniter instead of replacing it?

Unlike flame sensors (which can be cleaned with fine steel wool), hot surface igniters cannot be safely cleaned. The ceramic element is fragile, and any attempt to scrub or brush it will crack it. If your igniter is visibly dirty, a cracked element is often already present underneath the dust. Always replace rather than clean — an OEM Nordyne igniter is a $30 to $60 part that will give you 5 to 10 years of reliable starts.

My Nordyne furnace is from the 1990s — can I still get the right igniter?

Yes. Repair Clinic carries Nordyne and Intertherm igniter parts for models from the 1980s forward. Enter your complete model number on the product page, and the system will confirm availability and show you the exact igniter (including SiC vs. SiN type) that fits your furnace. Older Nordyne/Intertherm models often use SiC igniters, which are still in production.

Homeowner troubleshooting a furnace issue and how to replace the furnace's part.
Installing a new replacement furnace part after ordering online

Order Nordyne Furnace Igniter Parts Online

Shopping for Nordyne furnace igniter parts. Use your model number to get the right part. Whether you're a homeowner tackling a DIY project or a technician in need of specific parts, our comprehensive inventory ensures you find the exact match for your Nordyne furnace. Benefit from our No-Hassle 365-Day Returns, allowing you to return any uninstalled part within a year of purchase. Plus, our Price Match Guarantee ensures you pay the best price for genuine OEM replacement parts, matching any competitor's price for identical items. Easily locate parts using your furnace's model or part number and enjoy the convenience of same-day shipping when you order by 9:00 PM ET Trust Repair Clinic to keep your Nordyne furnace running smoothly with reliable igniter parts that ship out quickly, ensuring minimal downtime and maximum comfort. For more information on replacement parts, visit Repair Clinic's parts.

Nordyne Furnace Model Number: Where to Look

On Nordyne furnaces, look for the model number on the blower compartment door or the data plate inside the front access panel. You may also find it near the gas valve, depending on the furnace design. Record the complete model number, including letters and numbers, before searching for parts. Enter it in the model number search to pull up the parts matched to your unit, not just one part or part category. Using the full furnace model helps narrow Repair Clinic's catalog to compatible parts for the entire unit. That means fewer wrong orders and a faster repair.

Background Image

Online Repair Resources for Nordyne Furnace

Repair Clinic's online repair library helps Nordyne Furnace owners and technicians work through the diagnosis and installation. Troubleshooting videos, symptom articles, and part testing walkthroughs help you determine which component has failed. Once you know what to replace, use the model number lookup to confirm the exact OEM part, then follow the matching installation video from start to finish.

Related Furnace Repair Help Articles

Top Reasons Furnace is Not Igniting

Top Reasons Furnace is Not Igniting

A furnace that fails to ignite can leave your home in the cold. Common issues include a faulty igniter, malfunctioning flame sensor, or a defective draft inducer fan motor. Replacing furnace filters and cleaning furnace parts can help prevent these problems.

Why is My Furnace Not Working?

Why is My Furnace Not Working?

Learn why your furnace isn't working by understanding its ignition sequence and identifying common faulty parts like the igniter, flame sensor, or control board. This article provides practical repair tips and insights into each part's role in the heating process.

5 Causes of a Furnace Starting Then Stopping

5 Causes of a Furnace Starting Then Stopping

A gas furnace that starts and then stops unexpectedly can be frustrating, especially during cold weather. This article explains five common causes, including issues with the flame sensor, pressure switch, control board, draft inducer fan motor, or air flow. Learn how each cause may impact your furnace's operation and get tips to resolve the problem.