Blower motor, 1/5 HP, 60Hz 3.1 amp 1075 RPM's 3 Speed Open Enclosure 48Y Frame Single Phase CCW 3" Shaft
Grid is 1 inch square
Lennox Blower Motor 21L90
Lennox Blower Motor 21L90
Lennox Blower Motor 21L90
Lennox Blower Motor 21L90
Manufacturer Part

Lennox Blower Motor 21L90

Genuine OEM Part # 21L90RC Item # 2345766Alternative Part Number(s)
Manufacturer Part
Blower motor, 1/5 HP, 60Hz 3.1 amp 1075 RPM's 3 Speed Open Enclosure 48Y Frame Single Phase CCW 3" Shaft
Grid is 1 inch square
Lennox Blower Motor 21L90
Lennox Blower Motor 21L90
Lennox Blower Motor 21L90
Lennox Blower Motor 21L90
$423.78
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Blower motor, 1/5 HP, 60Hz 3.1 amp 1075 RPM's 3 Speed Open Enclosure 48Y Frame Single Phase CCW 3" Shaft
Loading stock status
$423.78
start a live chat with Repair Clinic customer support

This part 21L90 is compatible with:

Product Type:
Furnace
Brands:
Lennox

Related Articles & Videos

07:48
How This Part Works
Furnace Circulation Blower Fan Motor Replacement
02:28
Troubleshooting
Furnace Blower Not Running — Furnace Troubleshooting
01:49
Troubleshooting
Furnace Noisy Or Loud — Furnace Troubleshooting
00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
Frequently Bought with Blower Motor
LH680534 Flame Sensor
5303935066 Igniter
HH18HA493 Limit Switch
S1-03103010000 Control Board
Recommended Tools & Accessories
P291-0504 Run Capacitor

Blower Motor Customer Reviews

Common Problems Fixed by the Blower Motor

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Furnace blower not running

Likely

Furnace is noisy or loud

Likely

Furnace not blowing enough

Likely

Air handler is noisy or loud

Likely

Furnace circuit breaker keeps tripping

Likely

Air handler circuit breaker keeps tripping

Likely

Air handler blower not running/not turning on

Likely

Air handler is not blowing enough

Likely

Air handler coil icing up

Likely

Strange smells coming from furnace

Likely

Air handler has a burning smell

Likely

Air handler not cooling properly

Possible

Air handler not heating

Possible

Furnace not heating

About the Blower Motor

The blower motor blows air through the return vent, past the heat exchanger, and into the home’s venting. First, make sure that power is getting to the motor. If power is getting to the blower motor, but the motor does not run, the motor may be burned out. If the blower motor is burned out, replace it. If the blower motor hums, check the blower fan to ensure that it spins freely. If the blower fan is unobstructed but does not spin freely, replace the blower motor.

Shop by Brands

Repair Help by Brands and Product Type

Alternative Part Number(s)

Replaces Part Number 18M25
Replaces Part Number 21W84
Replaces Part Number 51W87
Replaces Part Number 86H66
Replaces Part Number 100648-01
Replaces Part Number 100648-02
Replaces Part Number 18M2501
Replaces Part Number 21L9001
Replaces Part Number 86H6601