Carrier 58PAV111-16116 Furnace Parts & Repair Help

Shop replacement repair parts for Carrier Furnace model 58MXA060-13112

icons/furnace
Brand:Carrier
Model:58MXA060-13112
Product:Furnace
115 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
HH18HA452 Flame Rollout Limit Switch
$12.69

Flame rollout limit switch, re-settable. opens at 250f

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
LH33ZS004 Igniter
$71.02

Carrier furnace igniter. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
LH680013 Flame Sensor
$32.14

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
P291-0504 Run Capacitor
$6.05

Run Capacitor, Single, Oval, 370 Volts, 5 Microfarads

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
325878-751 Control Board
$412.97

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
320725-756 Draft Inducer Motor
$703.35

Inducer motor assembly. This assembly is designed for 40, 60, 80, and 100 thousand BTU model furnaces. Your furnace's BTU rating may be listed on the model number tag. You can also determine the rating from your model number—the 3-digit number preceding the hyphen indicates the BTU rating.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
P251-0079 Grommet
$3.82

Grommet, motor mounting bracket. Sold as a single grommet but we suggest purchasing three since there are 3 holding the motor in place, and it’s a good practice to change all of them while the assembly is taken apart.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
HC41AE117 Blower Motor
$478.87

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/3
Voltage: 115
Full-Load Amperage: 5.2
Hertz: 60
RPM: 1075
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open
Shaft Length: 3.9”

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
HK06NB124 Pressure Switch
$112.10

Pressure switch, SPST 1.65"wc, 1/4 barbed connection

Go

Carrier 58MXA060-13112 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Carrier 58MXA060-13112 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
35 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
12 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
25 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Rollout Limit Switch
Igniter
Burner Tube
Flame Sensor

Keep your Carrier 58PAV111-16116 Furnace running reliably with genuine OEM replacement parts from Repair Clinic. Whether you’re troubleshooting a heating issue or replacing a worn-out component, we offer all the essential 58PAV111-16116 parts to restore peak performance.

This high-efficiency furnace model is known for its durability, but like any system, it requires occasional maintenance. Trust Repair Clinic for exact-match parts and helpful repair resources tailored to your specific Carrier unit.

Common Issues with the Carrier 58PAV111-16116 Furnace

1. Furnace Not Heating

Possible Causes:

  • Faulty igniter
  • Blown limit switch
  • Clogged air filter

Solution: Clean or replace the air filter and check the igniter and limit switch using a multimeter. Replace any failed components.

2. Blower Motor Not Running

Possible Causes:

  • Worn blower motor
  • Failed control board
  • Faulty capacitor

Solution: Inspect the motor and control board for continuity. Replace using OEM Carrier 58PAV111 parts.

3. Unit Keeps Cycling On and Off

Possible Causes:

  • Dirty flame sensor
  • Thermostat issues
  • Blocked vents or ducts

Solution: Clean the flame sensor and verify thermostat operation. Check vents for obstructions.

Key Carrier 58PAV111-16116 Replacement Parts

  • Igniter: Ensures the burner lights properly for heating cycles.
  • Control Board: Coordinates furnace operation and safety checks.
  • Blower Motor: Circulates warm air through the ducts.
  • Limit Switch: Prevents overheating by shutting off the burner when needed.
  • Flame Sensor: Detects flame to confirm safe ignition.

Why Choose Repair Clinic?

  • OEM Carrier Parts: Engineered specifically for your 58PAV111-16116 model.
  • Fast Shipping: Most orders ship the same day.
  • 365-Day Returns: Risk-free parts purchasing.
  • Expert Support: Chat or call us anytime for part identification help.

FAQs

1. How do I know if my 58PAV111-16116 igniter is bad?

  • If your furnace doesn’t ignite and you hear a click without flame, test the igniter with a multimeter for continuity.

2. What size filter fits the Carrier 58PAV111-16116?

  • Check your furnace’s manual or filter cabinet. Common sizes include 16x25x1, but always confirm before replacing.

3. How do I reset my Carrier furnace?

  • Turn off power at the breaker, wait 30 seconds, then turn it back on. Press the reset button on the control board if applicable.

4. Where can I find a 58PAV111-16116 parts diagram?

  • Visit Repair Clinic and search by model number to access exploded view diagrams and part details.

5. How often should I replace the flame sensor?

  • Clean the flame sensor annually. Replace it every 2–3 years or if cleaning does not restore function.