Carrier 58STA090-10114 Furnace Parts

Shop replacement repair parts for Carrier Furnace model 58STA090-10114

icons/furnace
Brand:Carrier
Model:58STA090-10114
Product:Furnace
94 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
LH680534 Flame Sensor
$51.99

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
KA56GR560 Grommet
$15.82

Furnace draft inducer mounting grommet. This grommet helps isolate the blower assembly from the furnace to reduce noise.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
LA660003 Fan Blade
$14.19

Furnace draft inducer motor cooling fan blade and clip. You may have to cut the old clip off to remove the fan blade.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
HK42FZ034 Control Board
$519.65

Carrier furnace control board, The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Go

Carrier 58STA090-10114 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Carrier 58STA090-10114 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
33 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
13 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
19 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Flame Rollout Limit Switch
Nameplate
Igniter

Restore dependable heat from your Carrier 58STA090-10114 furnace with model matched replacement parts from Repair Clinic. This 90,000 BTU class 58STA furnace is part of Carrier Global’s shared Carrier, Bryant, and Payne family. Start with the igniter, flame sensor, control board, and blower motor categories, then use the model specific parts list and diagram to confirm fit. Browse the full Carrier furnace parts catalog for additional replacement parts.

Carrier 58STA Platform, Revision Context, and Repair Guidance

The 58STA series is an 80% AFUE non-condensing gas furnace platform that uses metal venting rather than the PVC condensate system found on high-efficiency condensing furnaces. Nearby production suffixes can share many ignition and airflow components, but electronic controls and wiring revisions may differ. Confirm the complete model and serial information from the data plate before ordering a control board. For no heat complaints, read the control board fault code before replacing an igniter, flame sensor, or inducer component because the code identifies the stage where the heating sequence stopped. See furnace repair help for troubleshooting guidance.

Most Replaced Parts for This Carrier Furnace

Blower Motor and Run Capacitor

If the blower starts slowly, runs hot, or cannot maintain airflow, test the run capacitor before ordering a motor. A weak capacitor can produce the same symptoms at a fraction of the replacement cost. Match the microfarad rating printed on the installed capacitor and replace it when the measured value is outside the manufacturer tolerance. Find compatible Carrier blower motor parts.

Control Board and Fault Code Diagnosis

The control board sequences the inducer, ignition, gas valve, and blower. Record the LED fault code before disconnecting power, then compare it with the furnace service chart. A board should be considered only after the component named by the fault code and its wiring test correctly. Shop Carrier control board parts.

Flame Sensor and Short Cycling After Ignition

If the burners light and shut off within a few seconds, clean the flame sensor and inspect its wiring before replacement. Oxidation on the sensor rod can weaken the flame signal even when ignition is normal. Replace a pitted or damaged sensor with a model matched Carrier flame sensor.

Igniter and Draft Inducer Sequence

For a no ignition condition, verify that the inducer starts and the pressure switch circuit closes before testing the igniter. A cracked igniter or an inducer with worn bearings can stop the sequence at different stages, so fault code order matters. Browse Carrier igniter parts and Carrier inducer motor parts.

Why Choose Repair Clinic for Carrier Furnace Replacement Parts

  • Genuine OEM options for the Carrier family, with Bryant and Payne platform relationships noted where relevant.
  • Model and revision matching helps distinguish shared mechanical parts from suffix sensitive electronic components.
  • Diagnostic guidance prioritizes fault codes, airflow checks, and capacitor testing before higher cost replacements.
  • In-stock parts are supported by fast shipping, 365-day returns, and furnace repair help.

Carrier Furnace Parts FAQ

Which parts should I check first when this Carrier furnace will not ignite?

Read the control board fault code first. Then inspect the igniter, flame sensor, pressure switch circuit, and inducer sequence in the order indicated by the code before replacing parts.

Why does this furnace trip the high limit switch repeatedly?

Repeated limit trips usually point to restricted airflow. Check the filter, open supply and return registers, verify blower operation, and test the blower run capacitor before replacing the limit switch.

Can parts from nearby 58STA revisions be used on this furnace?

Many ignition and airflow components may be shared across nearby revisions, but control boards and wiring components can differ. Confirm the full model and suffix on the data plate before ordering electronic parts.

What should I inspect before replacing the draft inducer motor?

Confirm the inducer receives power, inspect the vent for blockage, check the pressure hose for cracks or restrictions, and listen for bearing noise. Replace the inducer only after those checks point to motor failure.