York Central Air Conditioner TCJD24S41S3A Parts

Shop replacement repair parts for York Central Air Conditioner model TCJD24S41S3A

York Central Air Conditioner TCJD24S41S3A Parts
Brand:York
Model:TCJD24S41S3A
Product:Central Air Conditioner
31 results
Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02440886000 Condenser Fan Motor
$215.11

Condenser fan motor, 1/8 HP 208-230Volts 60Hertz 0.8Amps 1075RPM Single Speed Closed Enclosure 42Y Frame Single Phase CW Rotation 2.5" Shaft. *** Updated motor - May require wires to be spliced on some applications.

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Go

York TCJD24S41S3A Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common York TCJD24S41S3A problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Cleaner
Condenser Fan Motor
Dual Run Capacitor

Ensure your TCJD24S41S3A central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The TCJD24S41S3A is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. York, Coleman HVAC, and Luxaire are all Johnson Controls brand designations sharing the same platform engineering and fully interchangeable service components. The TCJD24S41S3A is the two-ton configuration in the TCJD series, below the three-ton TCJD36S41S3A. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine York OEM parts for the TCJD24S41S3A including the York capacitor parts, York contactor parts, York fan motor parts, and York high-pressure switch parts. Browse the York central air conditioner parts catalog filtered by TCJD24S41S3A for the complete parts inventory.

TCJD24S41S3A: Two-Ton Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the TCJD24S41S3A. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the TCJD24S41S3A

Dual Run Capacitor for the TCJD24S41S3A

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

TCJD24S41S3A Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the TCJD24S41S3A

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the TCJD24S41S3A

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for TCJD24S41S3A Parts

  • Genuine York TCJD OEM Components: Two-ton dual run capacitors, contactors, and fan motors confirmed for the TCJD24S41S3A with Coleman HVAC and Luxaire cross-reference York central air conditioner parts.
  • R-410A Puron Platform: The TCJD24S41S3A uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the TCJD24S41S3A.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

TCJD24S41S3A Parts FAQ

What is the TCJD24S41S3A and what ton size is it?

The TCJD24S41S3A is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. York, Coleman HVAC, and Luxaire are all Johnson Controls brand designations sharing the same platform engineering and fully interchangeable service components. The TCJD24S41S3A is the two-ton configuration in the TCJD series, below the three-ton TCJD36S41S3A.

Why does my TCJD24S41S3A hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

How does the York TCJD24S41S3A differ from the TCJD36S41S3A?

The TCJD24S41S3A is a two-ton unit while the TCJD36S41S3A is a three-ton unit in the same York TCJD series. The dual run capacitor carries different compressor-section microfarad ratings between the two tonnages.

How often should I test the capacitor on the TCJD24S41S3A?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.