58STA110-12122 Carrier Parts & Furnace Repair Help

Shop replacement repair parts for Carrier Furnace model 58STA110-12122

icons/furnace
Brand:Carrier
Model:58STA110-12122
Product:Furnace
83 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
LH680534 Flame Sensor
$51.99

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
349336-763 Draft Inducer Motor
$287.75

Furnace draft inducer motor kit. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
KA56GR560 Grommet
$15.82

Furnace draft inducer mounting grommet. This grommet helps isolate the blower assembly from the furnace to reduce noise.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
LA660003 Fan Blade
$14.19

Furnace draft inducer motor cooling fan blade and clip. You may have to cut the old clip off to remove the fan blade.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
LA22ZA120 Blower Wheel
$254.83

Furnace blower wheel. 12" X 11.93" 1/2" Bore. The blower wheel blows air out of the furnace and through the house. The blower wheel is attached to the blower motor shaft with a set screw. If the set screw is loose, the blower wheel will wobble on the motor shaft and be noisy as it turns.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
HK42FZ034 Control Board
$519.65

Carrier furnace control board, The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Go

Carrier 58STA110-12122 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Carrier 58STA110-12122 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
31 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
16 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
19 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Flame Rollout Limit Switch
Nameplate
Igniter

Keep your Carrier 58STA110-12122 furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The 58STA110-12122 is a 110,000 BTU input, 80% AFUE upflow gas furnace from Carrier’s Star Plus series, one of Carrier’s most widely installed residential upflow furnace platforms. At 110,000 BTU this is a high-output residential furnace that cycles aggressively on cold days, accumulating igniter thermal cycles and inducer bearing hours faster per season than lower-output models. Repair Clinic stocks genuine Carrier OEM parts for the 58STA110-12122 including the Carrier igniter parts, Carrier flame sensor parts, Carrier draft inducer motor parts, Carrier blower motor parts, and Carrier control board parts. Browse the Carrier furnace parts catalog filtered by 58STA110-12122 for the complete parts inventory.

58STA110-12122: Carrier Star Plus 110,000 BTU Upflow Platform Service

The Carrier 58STA110 Star Plus series is an 80% AFUE upflow platform with the 110,000 BTU configuration at the top of the BTU range for this product line. At 110,000 BTU the inducer handles the greatest combustion gas volume in the Star Plus family, the furnace cycles most aggressively on cold days, and the igniter accumulates thermal cycles faster than lower-output siblings. The Carrier furnace troubleshooting guide covers fault code blink patterns for the 58STA platform control board.

Most Replaced Parts on the Carrier 58STA110-12122

Igniter for the Carrier 58STA110-12122

At 110,000 BTU the 58STA110-12122 cycles frequently in cold weather, accumulating igniter thermal stress at a higher rate per season than lower-output Star Plus models. Testing resistance at room temperature with power off confirms or rules out igniter failure in under two minutes before any other component is inspected.

Carrier 58STA110-12122 Flame Sensor

The flame sensor confirms sustained combustion by passing a micro-amp signal back to the control board after ignition. An oxidized sensor causes the furnace to ignite and shut off within seconds before lockout. Annual cleaning with fine steel wool extends sensor service life on the Star Plus platform and eliminates most early-season nuisance lockouts.

Draft Inducer Motor for the 58STA110-12122

The inducer on the 58STA110-12122 is sized for 110,000 BTU combustion gas throughput and must not be substituted with an inducer from a lower-output Star Plus configuration. At this output class the inducer accumulates more annual operating hours per heating season than 90,000 or 70,000 BTU siblings. Grinding at inducer startup indicates bearing failure that should be addressed before seizure causes a complete heating failure.

Blower Motor for the Carrier 58STA110-12122

The 110,000 BTU blower motor on the 58STA110-12122 must move adequate air volume across the heat exchanger to prevent limit switch trips. Test the run capacitor before ordering a replacement motor. A failing capacitor produces the same slow-start and reduced-speed symptoms as a failed motor winding at a fraction of the motor replacement cost.

Control Board for the Carrier 58STA110-12122

Read and document the LED fault code before ordering any replacement component. The 12122 configuration designation should be confirmed from the data plate when ordering a replacement board. A board that produces the same fault code after all identified components have tested good is a strong indicator of board failure.

Why Choose Repair Clinic for Carrier 58STA110-12122 Parts

  • Genuine Carrier Star Plus OEM Components: Igniters, flame sensors, and inducers confirmed for the 58STA110-12122 110,000 BTU 12122 cabinet configuration Carrier furnace parts.
  • Fault Code Diagnostic Resources: The Carrier furnace troubleshooting LED blink code chart for the 58STA platform is available alongside every part listing, eliminating the need to search elsewhere for the fault code chart.
  • High-Output Furnace Service Notes: 110,000 BTU igniter wear rates and inducer bearing inspection guidance specific to high-output residential installations are included with component listings.
  • Same-Day Dispatch: In-stock parts ordered by 9:00 PM ET ship the same day, with 365-day returns on all uninstalled components.

Carrier 58STA110-12122 Furnace Parts FAQ

What is the BTU output and efficiency of the Carrier 58STA110-12122?

The Carrier 58STA110-12122 is a 110,000 BTU input, 80% AFUE upflow gas furnace from Carrier’s Star Plus series. The 110 in the model designation identifies 110,000 BTU capacity and the 12122 identifies the cabinet width and production configuration.

How is the Carrier 58STA110-12122 different from the 58STA090?

The 58STA110-12122 delivers 110,000 BTU while the 58STA090 delivers 90,000 BTU on the same Star Plus platform. The inducer motor and heat exchanger are sized for each output class and must not be cross-substituted between the 110 and 090 configurations.

Why does my Carrier 58STA110-12122 inducer make noise at startup?

Grinding or squealing at inducer startup on the 58STA110-12122 indicates bearing wear accumulated over years of heating season operation. At 110,000 BTU the inducer handles more combustion gas volume per cycle than lower-output Star Plus models, placing additional annual hours on the bearing. Schedule replacement before complete seizure causes a total heating failure.

How do I read the fault code on the Carrier 58STA110-12122?

The control board LED on the 58STA110-12122 flashes a two-digit blink code. Count the first group of flashes, note the pause, then count the second group. Match the pattern to the fault code chart on the sticker inside the blower compartment access panel.