Lennox Central Air Conditioner XC14-036-230-3 Parts

Shop replacement repair parts for Lennox Central Air Conditioner model XC14-036-230-3

Lennox Central Air Conditioner XC14-036-230-3 Parts
Brand:Lennox
Model:XC14-036-230-3
Product:Central Air Conditioner
40 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
10F73 Contactor
$34.77

Contactor, 25 amp, 1-pole, 24 vac 60/50 hz coil

Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Go

Lennox XC14-036-230-3 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Lennox XC14-036-230-3 problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Dual Run Capacitor
Cleaner
Fan Motor

Maintain your XC14-036-230-3 central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The XC14-036-230-3 is a three-ton, 14 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The XC14 designation identifies Lennox’s premium 14 SEER R-410A residential outdoor condensing unit series. The 036 identifies three-ton capacity, 230 identifies the 230-volt power configuration, and 3 identifies the production revision. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Lennox OEM parts for the XC14-036-230-3 including the Lennox capacitor parts, Lennox contactor parts, Lennox fan motor parts, and Lennox high-pressure switch parts. Browse the Lennox central air conditioner parts catalog filtered by XC14-036-230-3 for the complete parts inventory.

XC14-036-230-3: Three-Ton, 14 Seer R-410A Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the XC14-036-230-3. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the XC14-036-230-3

Dual Run Capacitor for the XC14-036-230-3

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

XC14-036-230-3 Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the XC14-036-230-3

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the XC14-036-230-3

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for XC14-036-230-3 Parts

  • Genuine Lennox XC14 OEM Components: Three-ton run capacitors, contactors, and fan motors confirmed for the XC14-036-230-3 platform Lennox central air conditioner parts.
  • R-410A Puron Platform: The XC14-036-230-3 uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the XC14-036-230-3.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

XC14-036-230-3 Parts FAQ

What is the XC14-036-230-3 and what ton size is it?

The XC14-036-230-3 is a three-ton, 14 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The XC14 designation identifies Lennox’s premium 14 SEER R-410A residential outdoor condensing unit series. The 036 identifies three-ton capacity, 230 identifies the 230-volt power configuration, and 3 identifies the production revision.

Why does my XC14-036-230-3 hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

How does the Lennox XC14-036-230-3 differ from the 13ACX-036-230-2?

The XC14-036-230-3 is a 14 SEER unit while the 13ACX-036-230-2 is a 13 SEER unit, both at three-ton capacity. The higher-efficiency XC14 series may use different run capacitor specifications than the 13ACX series at the same tonnage.

How often should I test the capacitor on the XC14-036-230-3?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.