York Furnace TG9S040A08MP11A Replacement Parts

Shop replacement repair parts for York Furnace model TG9S040A08MP11A

York Furnace TG9S040A08MP11A Replacement Parts
Brand:York
Model:TG9S040A08MP11A
Product:Furnace
21 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$172.89

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$84.39

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02537499000 Flame Sensor
$71.91

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02649692000 Draft Inducer Motor
$273.58

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02440902000 Blower Motor
$427.36

3/4HP 115Volts 60Hz 11 amp 1060 RPM's 3 Speed Open Enclosure 48Y Frame Single Phase CCW 3.5" Shaft

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02440904000 Blower Motor
$339.24

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/3
Voltage: 115
Full-Load Amperage: 6.2
Hertz: 60
RPM: 1075
Speeds: 4
Rotation: Counterclockwise LE
Frame: 48
Enclosure: Open
Shaft Length: 4”

Go

York TG9S040A08MP11A Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common York TG9S040A08MP11A problems ― and their solutions. Do any of these look familiar?
Furnace not heating
26 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
11 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
15 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Igniter
Run Capacitor
Flame Sensor

Keep your York TG9S040A08MP11A furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The TG9S040A08MP11A is a 40,000 BTU input, 96% AFUE two-stage condensing gas furnace from York’s TG9S series, featuring an ECM blower motor for efficient, quiet operation at both low-fire and high-fire stages. Although it is the smallest output configuration in the TG9S condensing line, it requires the same condensate management, PVC venting, and two-stage pressure switch service as higher-output TG9S models. Repair Clinic stocks genuine York OEM parts for the TG9S040A08MP11A including the York igniter parts, York flame sensor parts, York draft inducer motor parts, and York control board parts. Browse the York furnace parts catalog filtered by TG9S040A08MP11A for the complete parts inventory.

York Two-Stage Condensing Furnace and Annual Condensate Maintenance

The York TG9S040A08MP11A produces acidic condensate from its secondary heat exchanger during every heating cycle, a condensate that must drain continuously through the trap and drain line without blockage. A blocked condensate drain is the single most common cause of pressure switch faults on this model. Annual flushing of the condensate trap before the heating season prevents the algae growth that causes most early-season pressure switch fault calls on the TG9S platform. The condensing-rated inducer on the TG9S040A08MP11A must tolerate moisture from condensate-laden flue gases which is a standard 80% AFUE inducer must never be substituted.

Most Replaced Parts on the York TG9S040A08MP11A

Condensate Trap for the TG9S040A08MP11A

Annual flushing of the condensate trap at the beginning of the heating season is the single most cost-effective preventive maintenance step for the TG9S040A08MP11A. Algae growth in the trap during the warm-weather idle period causes most pressure switch fault calls at early heating season startup which is a fault that a five-minute flushing procedure would have prevented entirely.

York TG9S040A08MP11A Draft Inducer Motor

The TG9S040A08MP11A uses a variable-speed condensing-rated inducer that operates at different speeds for low-fire and high-fire stages, tolerating moisture from condensate-laden flue gases that would quickly corrode a standard 80% AFUE inducer. Bearing failure presents as grinding at startup during the pre-purge phase, before the gas valve opens, and should be addressed before seizure causes a complete heating failure.

Pressure Switch Assembly for the TG9S040A08MP11A

Inspect and flush the condensate drain trap before replacing the pressure switch on any condensing furnace. The vast majority of TG9S040A08MP11A pressure switch fault calls trace to a blocked drain rather than a failed switch diaphragm. The TG9S040A08MP11A uses dual pressure switch verification for both low-fire and high-fire inducer speeds.

Hot Surface Igniter for the TG9S040A08MP11A

The igniter on the TG9S040A08MP11A functions identically to igniters in any York gas furnace regardless of the two-stage condensing platform complexity. Testing resistance at room temperature with power off quickly confirms or rules out igniter failure where an infinite ohm reading means the element is open-circuit and must be replaced.

Why Choose Repair Clinic for York TG9S040A08MP11A Parts

  • Genuine York TG9S OEM Components: Condensing-rated inducers, two-stage control boards, and pressure switch assemblies confirmed for the TG9S040A08MP11A 40,000 BTU platform — York furnace parts.
  • Condensate System Priority: Annual drain trap flushing guides prevent the most common TG9S040A08MP11A pressure switch fault from recurring at heating season startup. That is the most avoidable service call on this platform.
  • Two-Stage Condensing Service Resources: Low-fire and high-fire pressure switch diagnosis and condensate management guidance through furnace repair help.
  • 365-Day Returns: Return any uninstalled York part within a full year of purchase with no restocking fees.

York TG9S040A08MP11A Furnace Parts FAQ

What is the BTU output and efficiency of the York TG9S040A08MP11A?

The TG9S040A08MP11A is a 40,000 BTU input, 96% AFUE two-stage condensing gas furnace from York’s TG9S series, featuring an ECM blower motor for efficient, quiet airflow. At 40,000 BTU this is the smallest output configuration in the TG9S condensing line.

Is the York TG9S040A08MP11A related to Luxaire or Champion equivalents?

Yes. York, Luxaire, and Champion are all Johnson Controls residential HVAC brands sharing platform engineering. The TG9S040A08MP11A shares its condensing platform with related Luxaire and Champion two-stage models at the same BTU class.

Why does my TG9S040A08MP11A condensate drain back up at the start of the heating season?

Early-season condensate drain blockage on the TG9S040A08MP11A is almost always caused by algae growth in the condensate trap during warm months when the furnace was idle, not a failed pressure switch. Flush the condensate trap with clean water before the first heating call each season.

What type of venting does the York TG9S040A08MP11A require?

The TG9S040A08MP11A is a 96% AFUE condensing furnace requiring Schedule 40 PVC plastic venting for both exhaust and combustion air intake. Metal B-vent is not appropriate and it cannot tolerate the acidic condensate that forms in the flue gases of a condensing furnace.