York Furnace TG9S060B12MP11A Parts

Shop replacement repair parts for York Furnace model TG9S060B12MP11A

York Furnace TG9S060B12MP11A Parts
Brand:York
Model:TG9S060B12MP11A
Product:Furnace
18 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$172.89

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$84.39

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02537499000 Flame Sensor
$71.91

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-02440901000 Blower Motor
$361.36

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/2
Voltage: 115
Full-Load Amperage: 7.7
Hertz: 60
RPM: 1175
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02649692000 Draft Inducer Motor
$273.58

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02440900000 Blower Motor
$351.51

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1
Voltage: 115
Full-Load Amperage: 14.4
Hertz: 60
RPM: 1075
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open
Shaft Length: 3"

Go

York TG9S060B12MP11A Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common York TG9S060B12MP11A problems ― and their solutions. Do any of these look familiar?
Furnace not heating
21 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
11 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Gas Burner
Igniter
Run Capacitor

Get your York TG9S060B12MP11A back to reliable, efficient heat with genuine OEM replacement parts from Repair Clinic. The model decodes as a 60,000 BTU input furnace (060) in York’s TG9S series, a 95% AFUE single-stage condensing platform with a B width cabinet, a 1,200 CFM blower class (B12), and multi-position installation (MP). York shares this Johnson Controls platform with Coleman and Luxaire. Parts most often replaced include the pressure switch, the TG9S060B12MP11A igniter, the flame sensor, and the blower and draft inducer motors. Use the TG9S060B12MP11A parts list to confirm fit, then shop all York furnace parts.

TG9S060B12MP11A Condensing Platform and Service Requirements

As a condensing furnace, this unit extracts enough heat to turn flue vapor into liquid, so it vents through PVC and depends on a working condensate trap and drain. A blocked drain is the most common cause of pressure switch faults on the TG9S platform, which makes flushing the trap the first step in any lockout diagnosis. The blower is a fixed-speed PSC motor with a run capacitor, unlike the ECM motors in York’s TM9 models, so capacitor testing comes before motor replacement. Heat transfer happens in two stages: a primary TG9S060B12MP11A heat exchanger and a secondary condensing coil, both of which depend on clean combustion and good airflow. The TG9S060B12MP11A manual and TG9S060B12MP11A diagram document the drain layout and fault codes. For guided TG9S060B12MP11A repair, use the York furnace troubleshooting page.

Most Replaced Parts on This York Furnace

Pressure Switch Faults and Blocked Condensate Drains

The switch confirms the draft created by the inducer before ignition can proceed. When the condensate drain clogs, water backs up into the pressure port and the switch reads a false low draft even though the TG9S060B12MP11A draft inducer motor is running normally. Flush the trap and clear the drain line before testing the switch. Replace the pressure switch only after drainage is confirmed clear and the switch fails an electrical test.

Igniter Wear and Cold Weather No-Heat Calls

The hot surface igniter must reach ignition temperature within seconds of a heat call. An aging element with micro-fractures may light the burner on mild days but fail when cold air is drawn across it during pre-purge, so intermittent no-heat calls during the coldest weather often point here. Read the fault code, inspect the element, and replace the igniter if it glows unevenly.

Flame Sensor Contamination and Short Cycling

A furnace that ignites, runs a few seconds, and shuts off repeatedly before lockout usually has a contaminated TG9S060B12MP11A flame sensor. Oxide film on the rod reduces the signal below what the board needs to confirm flame. Clean the rod; if the three-attempt pattern returns, install a new flame sensor.

PSC Blower Motor and Run Capacitor

If the blower hums, starts slowly, or trips the limit switch on airflow, test the run capacitor first and replace it when it reads more than 5 to 10% below its rated value. Always match the microfarad rating printed on the installed capacitor. Replace the blower motor only when a good capacitor does not solve the problem.

Why Choose Repair Clinic for York TG9S060B12MP11A Parts

  • Genuine York OEM Parts: Components fit the Johnson Controls platform shared with Coleman and Luxaire. Browse all York furnace parts.
  • Condensing Platform Note: PVC venting and the condensate trap must be serviced alongside ignition parts on this 95% furnace.
  • Drain Before Switch Protocol: Flush the condensate trap before replacing a pressure switch, and test the capacitor before a blower motor.
  • Order TG9S060B12MP11A Parts Online: In-stock TG9S060B12MP11A replacement parts ship the same day with a 365-day return policy.

York TG9S060B12MP11A Furnace FAQ

Why does this furnace show a pressure switch fault when the inducer runs?

On condensing furnaces, a blocked condensate drain backs water into the pressure port tubing and creates a false low draft reading. Flush the trap and clear the drain line before testing or replacing the switch.

Is the TG9S060B12MP11A a two-stage or variable-speed furnace?

No. The TG9S series is a 95% single-stage furnace with a fixed-speed PSC blower motor and run capacitor. York’s TM9 models are the ones that use ECM blower motors.

What does the TG9S060B12MP11A furnace parts list include?

The list covers the igniter, flame sensor, draft inducer, pressure switches, control board, blower motor, capacitor, gas valve, and condensate components, each shown by position on the exploded diagram.

How do I know if the heat exchanger needs attention?

Rollout switch trips, scorching near the burners, or repeated limit trips with clean filters call for a professional inspection of the primary and secondary heat exchangers before the furnace is returned to service.