Shop replacement repair parts for York Furnace model G8D08012DNA11

Gas Burner Tube

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Genteq Run Capacitor 370 Volt Oval Single 7.5 MFD

Pressure switch tubing .313 OD .188 ID

High limit thermostat -140 open, 110 close

Orifice,burner drill size 45

Furnace blower motor. This single-phase motor has the following specifications:
Horsepower: 1/3
Voltage: 115
Full-Load Amperage: 6.2
Hertz: 60
RPM: 1075
Speeds: 4
Rotation: Counterclockwise LE
Frame: 48
Enclosure: Open
Shaft Length: 4”

Transformer, 120 volt primary 24 volt secondary 40 va

Flame rollout limit switch 320 degrees F open, manual reset

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Pressure Switch, -0.20/-0.40 SPNO contacts close on fall

Gas valve, 2-stage, J style

Grommet,d,split,0.5 diameter