York TG8S100C20MP11 Furnace Replacement Parts

Shop replacement repair parts for York Furnace model TG8S100C20MP11

York TG8S100C20MP11 Furnace Replacement Parts
Brand:York
Model:TG8S100C20MP11
Product:Furnace
40 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$172.89

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$84.39

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02537499000 Flame Sensor
$71.91

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02440900000 Blower Motor
$351.51

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1
Voltage: 115
Full-Load Amperage: 14.4
Hertz: 60
RPM: 1075
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open
Shaft Length: 3"

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02649695000 Draft Inducer Motor
$386.14

Combustion blower, 800-100 BTU. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go

York TG8S100C20MP11 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common York TG8S100C20MP11 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
28 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
11 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
18 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Gas Burner
Igniter
Flame Sensor

Maintain dependable heating from your York TG8S100C20MP11 furnace with genuine OEM replacement parts from Repair Clinic. The TG8S100C20MP11 is an 80% AFUE single-stage gas furnace from York’s TG8S series. York, Coleman HVAC, and Luxaire are all Johnson Controls brand designations sharing the same platform engineering. The igniter, flame sensor, control board, and inducer motor are the most frequently serviced components. Repair Clinic stocks genuine York OEM parts for the TG8S100C20MP11 including the York furnace igniter parts, York furnace flame sensor parts, York furnace control board parts, and York furnace inducer motor parts. Browse the York gas furnace parts catalog filtered by TG8S100C20MP11 for the complete parts inventory.

York TG8S100C20MP11: 80% AFUE Single-Stage Gas Furnace Service

Annual flame sensor cleaning is the most cost-effective preventive maintenance step for the York TG8S100C20MP11. A flame sensor coated with oxidation from normal combustion deposits cannot confirm ignition to the control board, causing the furnace to attempt ignition, fail to sense flame, and lock out. Cleaning with fine steel wool restores function without replacement in most cases. The gas furnace repair help section covers TG8S100C20MP11 igniter testing, flame sensor cleaning, and inducer motor diagnosis.

Most Replaced Parts on the York TG8S100C20MP11

Hot Surface Igniter for the York TG8S100C20MP11

The hot surface igniter heats to incandescence to light the burner. A cracked or failed igniter produces a no-heat lockout on the first ignition attempt.

Flame Sensor for the TG8S100C20MP11

Annual flame sensor cleaning with fine steel wool is the most cost-effective preventive step. A sensor that cannot be cleaned should be replaced.

Control Board for the York TG8S100C20MP11

Read the LED fault code displayed on the board before ordering a replacement. The TG8S100C20MP11A and TG8S100C20MP11B revisions may share the same control board.

Inducer Motor for the TG8S100C20MP11

The inducer motor must pre-purge combustion gases before ignition. A failed inducer motor triggers the pressure switch and causes a no-heat lockout before ignition begins.

Why Choose Repair Clinic for York TG8S100C20MP11 Parts

  • Genuine York TG8S OEM Components: Igniters, flame sensors, control boards, and inducer motors confirmed for the TG8S100C20MP11 with Coleman HVAC and Luxaire cross-reference York gas furnace parts.
  • Flame Sensor Cleaning Priority: Annual flame sensor cleaning with fine steel wool prevents the most common TG8S100C20MP11 ignition lockout complaint.
  • Gas Furnace Repair Resources: Igniter testing, flame sensor cleaning, and inducer motor diagnosis through gas furnace repair help.
  • 365-Day Returns: Return any uninstalled York part within a full year of purchase with no restocking fees.

York TG8S100C20MP11 Gas Furnace Parts FAQ

What is the York TG8S100C20MP11 and what are its specifications?

The York TG8S100C20MP11 is an 80% AFUE single-stage gas furnace from York’s TG8S series. York, Coleman HVAC, and Luxaire are all Johnson Controls brand designations sharing the same platform engineering and interchangeable service components.

Why does my York TG8S100C20MP11 not ignite?

A furnace that does not ignite most commonly has a failed hot surface igniter, a dirty flame sensor that cannot confirm ignition, or a pressure switch fault from a blocked condensate drain or failed inducer motor. Clean the flame sensor with fine steel wool before ordering a replacement.

How do I clean the flame sensor on the York TG8S100C20MP11?

Turn off power and gas to the furnace. Remove the single mounting screw holding the flame sensor rod, pull the sensor from the burner assembly, and clean the porcelain and metal rod with fine steel wool. Reinstall and test before ordering a replacement sensor.

Are York TG8S100C20MP11A and TG8S100C20MP11B parts interchangeable?

The TG8S100C20MP11A and TG8S100C20MP11B are successive production revisions of the same York TG8S100C20MP11 furnace. Most service components are interchangeable between both revisions. Always confirm using the complete model designation before ordering a control board.