Shop replacement repair parts for Kenmore Dryer model 110.87727701

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer idler pulley assembly. Includes bracket and pulley wheel

Dryer drum drive belt, 93 1/2 inches long, 4 ribs 3 grooves. The drive belt is a very long, slender belt that wraps all the way around the dryer drum, around a tension pulley, and then around the drive motor pulley. If the drum will not turn when the dryer is turned on the belt is likely broken.

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Dryer high limit thermostat and thermal fuse kit. If the dryer does not heat the most common cause is a blown thermal fuse. Both the thermostat and fuse can be tested to determine if either is defective.352 F fuse. L146.1-44.4c thermostat.

Dryer idler pulley wheel kit. The idler pulley puts tension on the drive belt. If the idler pulley fails to put the proper amount of tension on the belt, the dryer will not spin

Dryer heating element. If the dryer no longer heats then the heating element may have failed, but it is not the most common cause. The most common cause for a dryer to stop heating is a blown thermal fuse.

Drive motor kit - Note; the wiring connections may be different, comes with instructions

Hi-limit thermostat & thermistor assembly on heating element housing, L295-80F Thermistor should read around 50 to 60Kohms at room temperature.

Console

Cntrl-elec

Dryer door switch with wire harness and connector. This part has been discontinued by the manufacturer. However, there are service kits available for select models. These service kits include a new door switch, a new front panel, and installation instructions. See related items below.

Control board

Knob

Center user interface control.
*Per the manufacturer both the center and right user interface controls must be replaced together. Use part number off the right control to correctly identify the kit