HomePartsTrane PartsTrane Furnace Parts

Trane Furnace Parts

Find genuine OEM Trane Furnace Parts at Repair Clinic, with a broad in-stock selection from igniters and flame sensors to control boards and gas valves. Match the right part to your model, then order with 365-day returns, same-day shipping, and a price match guarantee.

Find the right part faster

Multiple models matched. Select your model to confirm fit.

2,439 results for 
Trane
Furnace
Sort:
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
RF000129 Control Board
$188.99

Ignition Control Board. The ignition control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
IGN00152 Igniter
$83.35

Replacement silicon-nitride igniter kit, gas furnace

Product is a manufacturer part
SWT01259 Limit Switch
$42.45

Thermal limit switch, open at 190 degrees, close at 160 degrees F

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
TRR01729 Transformer
$35.06

Transformer; 115v pri, 24v sec., 60hz, 35va, foot mount

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
KIT18110 Control Board
$448.17

Integrated single-stage furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SWT02124 Flame Rollout Limit Switch
$12.35

Switch; switch-flame rollout, 82 degrees c, 180 deg

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SWT01612 Limit Switch
$25.79

Thermal limit switch, open at 190 degrees, close at 160 degrees

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SFCAP15440 Run Capacitor
$16.70

Capacitor; 440 vac oval motor run, 15 mfd

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
BLW00889 Draft Inducer Motor
$506.84

Draft Inducer Motor, 1 stage. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SFCAP075440 Run Capacitor
$8.03

Capacitor; run, 7.5 mfd, 440v oval, w/o resistor

Go
Find. Fix. Finish.
Whether you're a pro or a novice, we've got you covered with the repair know-how and replacement Trane Furnace parts you need.
Genuine OEM Parts Supplier
Genuine OEM Trane Replacement Parts
Get peace of mind with the real thing—genuine OEM Trane Furnace parts.
365-Day Appliance Parts Return Policy
No-Hassle 365-Day Returns
Return uninstalled Trane Furnace parts and products for any reason within 365 days of purchase.
Same day shipping
Same-Day Shipping
Get the job finished. Order replacement Trane Furnace parts by 9:00 PM ET, and we'll ship them the same day.
Price Match Guarantee For Appliance Parts
Price Match Guarantee
We'll match any price offered by our direct competitors on all genuine OEM Trane Furnace replacement parts
Genuine OEM Parts Supplier
Genuine OEM Trane Replacement Parts
Get peace of mind with the real thing—genuine OEM Trane Furnace parts.

Trane Furnace Parts and Common Repairs

Trane furnaces are built for longevity and efficiency — but like all heating systems, key parts fail predictably over time. The good news: most repairs are straightforward when you have the right OEM part. Hot surface igniters, inducer motors, pressure switches, flame sensors, and control boards are the parts we ship most often for Trane units. Each one is model-specific, and using genuine Trane parts ensures proper voltage, resistance, and fit.

When your Trane furnace won't start, runs but produces no heat, or shuts down mid-cycle, the problem usually traces back to one of these high-failure parts. Enter your Trane model number into our parts finder — it will show the exact igniter type (SiC or Si carbide), the correct control board (CNT series), inducer motor assembly, and every pressure switch or limit switch engineered for your unit.

  • Hot surface igniter glows orange but goes out, or doesn't glow at all: Igniter has weakened and can no longer generate enough heat to open the gas valve.
  • Furnace starts then shuts off within seconds: Flame sensor has failed or is dirty; clean first, then replace if the problem persists.
  • Pressure switch trips repeatedly or won't reset: Check for blocked drain lines and cracked hoses first; if clear, the switch itself has likely failed.
  • Inducer motor runs but furnace won't ignite: Motor assembly may be failing, or the motor coupler is broken — verify with your model number.
  • No power to furnace or display is dead: Start with the 24V transformer and control board diagnostics — CNT boards are model-specific and must be an exact OEM match.

Find Replacement Trane Furnace Parts Online by Model or Part Number


Popular Trane Furnace Models

Trane Furnace Parts FAQ

What's the difference between SiC and SiN igniters, and how do I know which one my Trane furnace uses?

Trane furnaces use either silicon carbide (SiC) or silicon nitride (SiN) hot surface igniters depending on the model and age. The physical appearance can look similar, but they have different electrical resistances and operating temperatures — using the wrong type will cause ignition failure or premature burnout. Always enter your exact model number into our parts finder; it will display the correct igniter type and part number. Never assume two Trane models use the same igniter.

How do I find my Trane furnace model number, and why does it matter so much for parts?

Your Trane model number is on a nameplate attached to the furnace cabinet — usually on the front or side panel. It's a combination of letters and numbers (e.g., XC95m, XR95). This model number determines which control board (CNT series), igniter type, inducer motor assembly, pressure switch, and limit switch are correct for your unit. Trane's product line spans decades with different part configurations — the model number is one reliable way to help ensure exact compatibility. Take a photo of the nameplate and use it when shopping on Repair Clinic.

What does it mean when my Trane furnace displays an error code on the LED, and how do I fix it?

Trane furnaces use LED blink codes on the integrated furnace control (IFC) board to communicate faults. Count the blinks in a sequence — for example, three short blinks followed by a pause usually points to a specific issue like a pressure switch failure, flame sensor problem, or gas valve fault. Your furnace manual or our parts finder will decode the blink pattern for your model. Once you've identified the fault, the correct OEM replacement part — whether it's a pressure switch, flame sensor, or control board — will clear the error when installed correctly.

Can I use aftermarket or generic parts in my Trane furnace, or do I need genuine OEM parts?

Trane's factory-certified positioning and the precision engineering of its communicating control systems mean OEM parts are strongly recommended. Generic igniters or aftermarket control boards often fail to match exact resistance, voltage requirements, or sensor specifications — which can cause intermittent ignition, safety lockouts, or shortened part life. Trane parts are designed to work as an integrated system. Genuine Trane OEM parts from Repair Clinic help ensure fit, function, and model-specific fit and performance.

Homeowner with safety glasses and electrical gloves on inspects a furnace HVAC system with a flashlight to troubleshoot the problem
Amana furnace replacement parts ready for HVAC installation

Order Trane Furnace Replacement Parts Online

Keep your Trane furnace running efficiently with genuine Trane replacement parts from Repair Clinic. We offer Trane furnace blower motors, control boards, igniters, gas valves, and more, all designed for Trane furnace models. Search by model or part number to find the right parts fast.

Trane Furnace Model Number: Where to Look

On Trane furnaces, look for the model number on the blower compartment door or another nameplate attached to the cabinet. The label may also be inside the front access panel, near the burner assembly, or on a side panel. Record every letter and number exactly, including any hyphens. Type it into the search bar and our model number lookup narrows the catalog to parts made for your unit. This model number applies across the furnace and its associated parts, so you can compare the full selection with confidence. You get parts that fit the first time.

Background Image

Trane Furnace Troubleshooting Videos and Repair Articles

Repair Clinic's online repair library is where Trane Furnace owners and technicians go to diagnose the problem and complete the fix. Video walkthroughs, symptom articles, part testing tutorials, and exploded-view diagrams cover the most common repairs from start to finish. Model number lookup confirms the exact OEM part before you order.

Related Furnace Repair Help Articles

How To Replace a Circuit Board in Your Furnace

How To Replace a Circuit Board in Your Furnace

Replacing a malfunctioning furnace circuit board may be the key to restoring your heating system's functionality. This article provides a clear guide to understanding the role of the circuit board in a furnace's ignition sequence, common reasons for circuit board failure, and step-by-step instructions for replacing a furnace circuit board.

Why is My Furnace Not Working?

Why is My Furnace Not Working?

Learn why your furnace isn't working by understanding its ignition sequence and identifying common faulty parts like the igniter, flame sensor, or control board. This article provides practical repair tips and insights into each part's role in the heating process.

5 Causes of a Furnace Starting Then Stopping

5 Causes of a Furnace Starting Then Stopping

A gas furnace that starts and then stops unexpectedly can be frustrating, especially during cold weather. This article explains five common causes, including issues with the flame sensor, pressure switch, control board, draft inducer fan motor, or air flow. Learn how each cause may impact your furnace's operation and get tips to resolve the problem.