Find the right part faster
Multiple models matched. Select your model to confirm fit.

The 349336-761 Draft Inducer Motor is essential for enhancing the efficiency of your furnace's ventilation system. To prevent carbon monoxide from leaking into your home, we recommend replacing the draft inducer gasket or using high-temp silicone sealant when servicing the motor or inducer fan.

Furnace draft inducer motor kit. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor with cooling fan. Be aware that the screw holes are not threaded—you will need to use self-tapping screws to install the motor.

Inducer motor assembly. This assembly is designed for 40, 60, 80, and 100 thousand BTU model furnaces. Your furnace's BTU rating may be listed on the model number tag. You can also determine the rating from your model number—the 3-digit number preceding the hyphen indicates the BTU rating.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Draft inducer fan motor. *Motor only. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Motor, induced draft

1/3 HP 208-230V 1075 RPM, 3 Speed Blower Motor

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Motor induced draft

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.
The draft inducer motor is the first part to run in your Bryant furnace's heating cycle. It pulls exhaust gases safely out of the heat exchanger and into the vent pipe — and when it fails, you'll often hear rattling, grinding, or a pressure switch error before your furnace shuts down. A weak or failed inducer motor forces your pressure switch to trip as a safety measure, blocking ignition entirely.
Replacing the draft inducer motor assembly is one of the most common Bryant furnace repairs. The motor comes as a complete assembly with the wheel, housing, and mounting bracket. Always verify your model number to ensure the correct horsepower rating and flange dimensions — inducer motors are not interchangeable across all Bryant models.
Find your Bryant furnace model number on the rating plate inside the unit or on your system documentation, then enter it into our parts finder to locate the exact replacement draft inducer motor assembly.
The draft inducer motor is a small but critical motor that evacuates combustion gases from your furnace's heat exchanger before the burner ignites. It runs first in the ignition sequence, pulling air through the heat exchanger and vent pipe to create a safe draft. Most Bryant inducer motors fail due to bearing wear, electrical coil burnout, or a broken fan wheel — the plastic wheel can crack from impact or age. Once it fails, the pressure switch detects insufficient draft and prevents the furnace from firing as a safety measure.
A pressure switch error is a symptom, not always the root cause. To troubleshoot: listen carefully when the furnace tries to start. A grinding or rattling noise during the initial 30 seconds means the inducer motor is the problem. If the motor spins normally but the pressure switch still trips, the switch itself or the vent line blockage is the culprit. A cracked inducer wheel, however, will spin but produce weak airflow. Always rule out a blocked or kinked vent pipe first — that's the #1 false pressure switch error.
Bryant furnaces use different inducer motor horsepower ratings depending on the furnace size and model series. A 0.5 HP motor won't work on a unit designed for 0.75 HP. The motor also has specific flange and mounting dimensions — wrong ones won't fit the furnace housing or won't align with the vent collar. Your model number tells us the exact assembly to send. Look for the rating plate on the furnace itself, or check your documentation.
OEM Bryant inducer motors come as a complete assembly — motor, wheel, housing, and mounting bracket all together. This is actually the most reliable approach because the wheel balance and motor-to-wheel alignment are factory-set. Trying to reuse a housing or wheel with a new motor can cause imbalance, noise, and early failure. Buy the complete assembly and you eliminate troubleshooting guesswork.


Purchasing Bryant furnace draft inducer motors online is reliable with Repair Clinic. Our platform offers easy lookup by model or part number, ensuring you find the exact part you need to keep your furnace operating efficiently. Benefit from our No-Hassle 365-Day Returns, allowing you to return uninstalled parts within 365 days for any reason. Plus, our Price Match Guarantee ensures you won't overpay, as we match prices from direct competitors on genuine OEM replacement parts. Place your order by 9:00 p.m., and we'll ship it the same day, so you can get your furnace back up and running without delay. Trust Repair Clinic for all your Bryant furnace part needs, and enjoy peace of mind with with same-day shipping and access to our online repair library of guides, videos, and part diagrams.
On Bryant furnaces, look for the model number on the rating plate inside the front access panel or on the blower compartment door. You may need to remove the panel to see the label, so turn off power to the furnace first and keep the complete model number, including letters and numbers. If the label is hard to read, check your installation paperwork or owner's manual. Type it into our model number lookup and the catalog narrows to parts made for your unit. This filters the full Bryant furnace parts selection, not just draft inducer motors, to parts matched to your specific furnace. You order with confidence knowing the fit is right.

Bryant Furnace problems usually trace back to a handful of common causes, and Repair Clinic's online resources help you find them fast. Symptom articles, diagnostic videos, and part testing walkthroughs guide you through the checks that isolate the failed part. Once identified, look it up by model number and follow the installation guide to complete the fix.

A furnace that fails to ignite can leave your home in the cold. Common issues include a faulty igniter, malfunctioning flame sensor, or a defective draft inducer fan motor. Replacing furnace filters and cleaning furnace parts can help prevent these problems.

A malfunctioning furnace blower fan motor can disrupt your heating system, but replacing it doesn't have to be daunting. This article explains the blower motor's role in circulating air through your home and provides detailed, step-by-step guidance for safely removing and installing a new furnace blower fan motor.

A gas furnace that starts and then stops unexpectedly can be frustrating, especially during cold weather. This article explains five common causes, including issues with the flame sensor, pressure switch, control board, draft inducer fan motor, or air flow. Learn how each cause may impact your furnace's operation and get tips to resolve the problem.