Video & Articles: Appliance & Equipment RepairYork Furnace High-Limit Thermostat Replacement S1-02541320000

York Furnace High-Limit Thermostat Replacement S1-02541320000

01:24
This video provides step-by-step repair instructions for replacing the high-limit thermostat on a York furnace. The most common reasons for replacing the high-limit thermostat

All of the information for this high-limit thermostat replacement video is applicable to the following brands:
York, Luxaire, Fraser-Johnson, Coleman

Step By Step Instructions

1
To replace the high limit thermostat on your furnace first shut off the power to the furnace.
2
Next, rotate the knobs securing the combustion chamber panel and pull the panel off.
3
Now disconnect the wires from the old high limit thermostat.
4
Remove the mounting screws to release the old thermostat.
5
Install the new high limit thermostat by positioning it on the combustion chamber housing then replace the mounting screws to secure it.
6
Connect the wires to the new thermostat.
7
Reposition the combustion chamber panel and rotate the knobs to secure.
8
You’re now ready to restore power to the furnace and confirm that it’s functioning properly.
Description
This video provides step-by-step repair instructions for replacing the high-limit thermostat on a York furnace. The most common reasons for replacing the high-limit thermostat

All of the information for this high-limit thermostat replacement video is applicable to the following brands:
York, Luxaire, Fraser-Johnson, Coleman
Step-By-Step Instructions
1
To replace the high limit thermostat on your furnace first shut off the power to the furnace.
2
Next, rotate the knobs securing the combustion chamber panel and pull the panel off.
3
Now disconnect the wires from the old high limit thermostat.
4
Remove the mounting screws to release the old thermostat.
5
Install the new high limit thermostat by positioning it on the combustion chamber housing then replace the mounting screws to secure it.
6
Connect the wires to the new thermostat.
7
Reposition the combustion chamber panel and rotate the knobs to secure.
8
You’re now ready to restore power to the furnace and confirm that it’s functioning properly.

Applicable Product Model

Parts Needed
Total$0.00

Related Articles & Videos

04:47
Part Replacement
York Furnace Gas Valve Assembly Replacement #S1-32544123000
05:32
Part Replacement
York Furnace Blower Motor Replacement #S1-02435735000
01:55
Part Replacement
York Furnace Won't Start? Furnace Repair #S1-33103010000
04:33
Part Replacement
York Furnace Noisy? Replace Blower Wheel #S1-02619654709
01:23
Part Replacement
York Furnace Isn't Heating? Replace Flame Sensor #S1-02537499000