Step By Step Instructions

1
To replace the transformer on your furnace first turn off the power to the furnace.
2
Next, rotate the knobs securing the blower chamber panel and pull the panel off.
3
Note the orientation of the transformer wires and disconnect them from the transformer.
4
Now remove the screws securing the transformer to the mounting plate and pull the old transformer off.
5
Install the new transformer by aligning it on the mounting plate and securing it with the screws.
6
Be sure to secure the control board grounding wire as well.
7
Connect the wires to the appropriate terminals.
8
Reposition the blower chamber panel and rotate the knobs to secure.
9
You’re now ready to restore power to the furnace and confirm that it’s functioning properly.
Description
This video provides step-by-step instructions for replacing the transformer on York, Coleman, and Luxaire furnaces. The most common reason for replacing the transformer is if it blows, which causes the furnace to be unable to run.

All of the information in this transformer replacement video is applicable to the following brands: Coleman, York, Luxaire
Step-By-Step Instructions
1
To replace the transformer on your furnace first turn off the power to the furnace.
2
Next, rotate the knobs securing the blower chamber panel and pull the panel off.
3
Note the orientation of the transformer wires and disconnect them from the transformer.
4
Now remove the screws securing the transformer to the mounting plate and pull the old transformer off.
5
Install the new transformer by aligning it on the mounting plate and securing it with the screws.
6
Be sure to secure the control board grounding wire as well.
7
Connect the wires to the appropriate terminals.
8
Reposition the blower chamber panel and rotate the knobs to secure.
9
You’re now ready to restore power to the furnace and confirm that it’s functioning properly.

Applicable Product Model

Parts Needed
Total$0.00

Related Articles & Videos

04:47
Part Replacement
York Furnace Gas Valve Assembly Replacement #S1-32544123000
05:32
Part Replacement
York Furnace Blower Motor Replacement #S1-02435735000
01:55
Part Replacement
York Furnace Won't Start? Furnace Repair #S1-33103010000
04:33
Part Replacement
York Furnace Noisy? Replace Blower Wheel #S1-02619654709
01:23
Part Replacement
York Furnace Isn't Heating? Replace Flame Sensor #S1-02537499000